摘要 In the development of hybrid HVDC and HVAC transmission lines,the study of radio interference is an important issue.Positive corona current pulses from high voltage transmission lines are the main source of radio interference.In this paper,the design of a wire-cylinder gap electrode system is presented to study the influence of AC voltage on the characteristics of positive corona current pulses.The study shows that the mode of the current pulses is different from that of either DC or AC corona discharge.Waveform parameters of the pulses,such as rise time,half wave time,duration time,repetition rates,average amplitude,and time intervals of secondary pulses are all statistically analyzed in this study.The empirical formulas for the repetition rates with different AC voltages are presented.A theoretical explanation based on an ion cloud model is given to reveal the mechanism behind the influence of AC voltage on positive corona discharge.The experimental results could provide some references for the prediction of radio interference from hybrid AC/DC transmission lines.
出处 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第4期58-65,共8页 中国电机工程学会电力与能源系统学报(英文)
基金 supported by National Basic Research Program of China(973 Program)under Grant 2011CB209402.
  • 相关文献

参考文献1

二级参考文献20

  • 1万保权,邬雄,路遥,张小武.交流同塔双回特高压输电线路无线电干扰研究[J].高电压技术,2006,32(12):59-61. 被引量:21
  • 2Maruvada P S. Corona performance of high-voltage transmission lines[M]. Baldoek: Research Studies Press, 2000: 111-112, 114, 118, 147-154, 226-227, 257.
  • 3Kolcio N, Di-Placido J, Haas R J, et al. Long term audible.noise and radio noise performance of American electric power's operating 765kV lines[J]. IEEE Transactions on Power Apparatus and Systems, 1979, PAS-98(6): 1853-1859.
  • 4Juette G W, Charbonneau H, Dobson H I, et al . CIGRE/IEEE survey on extra high voltage transmission line radio noise[J]. IEEE Transactions on Power Apparatus and Systems, 1973, 92(3): 1029-1042.
  • 5IEC. TR CISPR 18-3-2010, Radio interference characteristics of overhead power lines and high-voltage equipment(S]. Pretoria: SABS Standards Division, 2010.
  • 6Haussmann B. Interference produced by corona effect of electric systems(R]. Paris: CIGRE Committee, 1974.
  • 7Chartier V L. Comprehensive empirical formulas for predicting EMI from overhead power line corona(C]// Proceedings of the 1988 U.S.-Japan Seminar on Electromagnetic Interference in Highly Advanced Social Systems. Honolulu, Hawaii State: the NSF and the Japan Society for the promotion of Science, 1988: 5.1-5.12.
  • 8Juette G W. Comparison of radio interference noise prediction methods with CIGRE/IEEE survey results [J]. IEEE Transactions on Power Apparatus and Systems, 1973, 92(3): 1029-1042.
  • 9Olson R G, Schennum S D, Chartier V L. Comparison of several methods for calculating power line electromagnetic interference levels and calibration with long term data[J]. IEEE Transactions on Power Delivery, 1992, 7(2): 903-913.
  • 10Trinh N G, Maruvada P S. A method of predicting the corona performance of conductor bundles based on cage test results[J]. IEEE Transactions on Power Apparatus and Systems, 1977, 96(1): 312-325.

共引文献7

同被引文献42

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部