摘要
采用自动沥青软化点测定仪测量了热熔胶黏剂的软化点,讨论了重复性测量、软化点测定仪温度偏差、设备误差、升温速度等因素带来的不确定度分量,计算了环球法测量热熔胶黏剂软化点的合成标准不确定度及扩展不确定度。当包含因子k=2、置信概率p=95%时,热熔胶黏剂软化点的不确定度为1.6℃。不确定度主要来源于软化点测定仪设备误差。
The softening point of hot melt adhesive was measured by automatic asphalt softening point tester.The uncertainty components caused by repeatability measurement,temperature deviation of softening point tester,equipment error,heating rate and other factors were discussed.The combined standard uncertainty and expanded uncertainty of measurement of softening point of hot melt adhesive by universal method were calculated.When the inclusion factor k is 2 and the confidence probability p is 95%,the uncertainty of softening point of hot melt adhesive is 1.6℃.
作者
李东阳
程玉魁
冯少广
潘腾
任向辉
孙晁
LI Dong-yang;CHENG Yu-kui;FENG Shao-guang;PAN Teng;REN Xiang-hui;SUN Chao(Pipeline R&D Center,PipeChina North Pipeline Company,Langfang 065000,China;Hebei Anke Engineering and Technology Co.,Ltd.,Shijiazhuang 050000,China;PipeChina North Pipeline Company,Langfang 065000,China)
出处
《塑料工业》
CAS
CSCD
北大核心
2021年第S01期113-115,共3页
China Plastics Industry
关键词
软化点
环球法
不确定度评定
热熔胶黏剂
Softening Point
Ring and Ball Method
Evaluation of Uncertainty