摘要
论文旨在解决机组启动前在利用辅助蒸汽进行给水泵汽轮机(BFP-T)超速试验过程时,由于小汽轮机与给水泵尚未连接,小汽轮机转速极难控制,常常需要热控人员通过非常规的信号强制来进行控制,容易导致汽轮机转速飞升,严重威胁设备安全运行的问题。论文设计了针对该项试验的创新全自动程序管理,实现"一键投入、全程自动",使整个试验过程安全有序进行的方式。结果表明,通过对给水泵汽轮机超速试验逻辑的优化设计,杜绝了人为强制信号的时间及误操作所带来的风险,提高了给水泵汽轮机超速试验的效率及成功率。
The paper aims to solve the problem that during the overspeed test of the boiler feed water pump(BFP-T)using auxiliary steam before unit start-up,the small turbine speed is extremely difficult to be controlled because the small turbine is not yet connected to the boiler feed water pump,and often requires the thermal control personnel to enforce control through unconventional signals,which easily leads to a soaring turbine speed and seriously threatens the safe operation of the equipment.Aiming at this test,this paper designs a method,which has innovative full-automatic program management,realizes"one key can be put in,the whole process automatically",and makes the whole test process safe and orderly.The results show that through the optimized design of the overspeed test logic of the boiler feed water pump turbine,the risks caused by the timing and misuse of artificially forced signals are eliminated,and the efficiency and success rate of the overspeed test of the boiler feed water pump turbine are improved.
作者
李强
LI Qiang(Zhuhai Power Plant,Guangdong Energy Group Co.,Ltd.,Zhuhai 519000,China)
出处
《中小企业管理与科技》
2021年第21期164-165,共2页
Management & Technology of SME
关键词
超速试验
全自动
汽动给水泵
overspeed test
full-automation
turbine driven boiler feed water pump