期刊文献+

Improved Coordinated Control Approach for Evolved CCC-HVDC System to Enhance Mitigation Effect of Commutation Failure 被引量:1

原文传递
导出
摘要 The evolved capacitor commutated converter(ECCC),embedded with anti-parallel thyristors based dual-directional full-bridge modules(APT-DFBMs),can effectively reduce commutation failure(CF)risks of line-commutated converter-based high voltage direct current(HVDC)and improve the dynamic responses of capacitor-commutated converterbased HVDC.This paper proposes an improved coordinated control strategy for ECCC with the following improvements:(1)under normal operation state,series-connected capacitors can accelerate the commutation process,thereby reducing the overlap angle and increasing the successful commutation margin;(2)under AC fault conditions,the ability of ECCC to mitigate the CF issue no longer relies on the fast fault detection,since the capacitors inside the APT-DFBMs can consistently contribute to the commutation process and further reduce the CF probability;(3)the inserted capacitors can output certain amount of reactive power,increase the power factor,and reduce the required reactive power compensation capacity.Firstly,the proposed coordinated control approach is presented in detail,and the extra commutation voltage to mitigate the CFs provided by the proposed control approach and an existing approach is compared.Secondly,the mechanism of the improved control approach to accelerate commutation process and improve the power factor is analyzed theoretically.Finally,the detailed electromagnetic transient(EMT)simulation in PSCAD/EMTDC is conducted to validate the effectiveness of the proposed coordinated control.The results show that the proposed approach can present a further substantial improvement for ECCC,especially enhancing the CF mitigation effect.
出处 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第2期338-346,共9页 现代电力系统与清洁能源学报(英文)
  • 相关文献

参考文献6

二级参考文献67

  • 1毛晓明,管霖,张尧,吴小辰,彭显刚.含有多馈入直流的交直流混合电网高压直流建模研究[J].中国电机工程学报,2004,24(9):68-73. 被引量:117
  • 2蔡泽祥,朱浩骏,白雪峰,倪以信.多馈入直流输电系统的动态特性及稳定控制与分析[J].华北电力大学学报(自然科学版),2004,31(5):1-8. 被引量:27
  • 3陈树勇,李新年,余军,李涛,吕鹏飞,印永华.基于正余弦分量检测的高压直流换相失败预防方法[J].中国电机工程学报,2005,25(14):1-6. 被引量:158
  • 4徐政,陈海荣.电压源换流器型直流输电技术综述[J].高电压技术,2007,33(1):1-10. 被引量:369
  • 5Arne Hansen, Henrik havemann. Decreasing the commutation failure frequency in hvdc transmission systems[J]. IEEE Trans on Power Delivery, 2000, 15(3): 1022-1026.
  • 6Lidong Zhang, Lars Dofans. A novel method to mitigate commutation failures in HVDC systems[C].2002 International Conference on Power System Technology Proceedings. Kunming,China, 2002: 51-56.
  • 7Thio C V, Davies J B, Kent K I. Commutation failures in HVDC transmission systems[J]. IEEE Trans. on Power Delivery, 1996,11 (2):946-957.
  • 8Kristmundsson G M, Carroll D P. The effect of AC systems frequency spectrum on commutation failure in HVDC inverter[J].IEEE Trans. on Power Delivery, 1990,5 (2): 1121-1128.
  • 9Tamai S, Naitoh H, Ishiguro F et al. Fast and predictive HVDCextinction angle control[J]. IEEE Transactions on Power Systems,1977, 12(3): 1268-1275.
  • 10Denis L H A, Andersson G. Voltage stability analysis of multi-infeed HVDC system[J]. IEEE Transactions on Power Delivery, 1997,12(3): 1309-1318.