摘要
为了更好的评定医用冷冻离心机的计量性能指标,保证其溯源可靠性,本文简单阐述了医用冷冻离心机的对于转速、振动、噪声、温度的校准方法,为相关计量机构开展类似问题研究提供了参考和借鉴。
In order to better evaluate the metrological performance of the medical refrigerated centrifuge and ensure its traceability reliability,this paper briefly introduce the calibration methods of rotational speed,vibration,noise and temperature of the medical refrigerated centrifuge,which provides the reference for relevant metrological institutes to do similar research.
出处
《计量与测试技术》
2021年第6期1-3,6,共4页
Metrology & Measurement Technique
关键词
医用冷冻离心机
转速
振动
噪声
温度
the medical refrigerated centrifuge
rotational speed
vibration
noise
temperature