住宅负荷节能效果模拟研究——以黄山市为例 被引量:1

Simulation Study on Energy Saving Effect of Residential Load-Taking Huangshan City as an Example
下载PDF
导出
摘要 以黄山市居住建筑为研究对象,使用DeST软件,讨论不同工况下传热系数与换气次数对居住建筑负荷的影响。结论如下:建议选用当换气次数为2.0次/h,传热系数接近0.2W/(m^(2)·K)时,对建筑冷热负荷影响最小;当换气次数分别从4.5次/h降低到4.0和2.0次/h时,其采暖季节能率分别为12.30%和61.33%。 Taking residential buildings in Huangshan City as the research object,using DeST software,discuss the influence of heat transfer coefficient and air exchange frequency on residential building load under different working conditions.The conclusion is as follows:It is recommended that when the air exchange frequency is 2.0 times/h and the heat transfer coefficient is close to 0.2 W/(m^(2)·K),the impact on the cooling and heating load of the building is minimal,when the air exchange frequency is reduced from 4.5 times/h to 4.0 and 2.0 times/h,the heating energy saving rate is 12.30% and 61.33% respectively.
作者 曹静怡 胡浩威 杨帆 崔倩 CAO Jingyi;HU Haowei;YANG Fan;CUI Qing(School of Civil Engineering,Anhui Jianzhu University,Hefei 230601,China;Anhui BIM Engineering Center,Hefei 230601,China;School of Environmental and Energy Engineering,Anhui Jianzhu University,Hefei 230601,China;Anhui Institute of Advanced Technology of Green Building,Hefei 230601,China;Anhui Province Key Laboratory of Intelligent Building and Building Energy Saving,Hefei 230022,China)
出处 《佳木斯大学学报(自然科学版)》 CAS 2021年第4期9-13,共5页 Journal of Jiamusi University:Natural Science Edition
基金 "十三五"国家重点研发计划项目(2017YFC0702600) 智能建筑与建筑节能安徽省重点实验室开放课题(IBES2018KF06)。
关键词 换气次数 传热系数 节能率 ventilation frequency heat transfer coefficient energy saving rate
  • 相关文献

参考文献5

二级参考文献21

共引文献102

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部