污泥焚烧作为目前污水处理厂后期产物污泥的一种主流处理工艺,可实现污泥最彻底的减量化。污泥焚烧工艺复杂,涉及人身、设备和环境等多方面的安全性,其焚烧系统的保护控制尤为重要。以白龙港污泥处理处置二期工程鼓泡流化床污泥焚烧炉的保护控制为研究对象,对其主要的保护控制进行分析和总结,建立了几大保护逻辑关系,提出了合理的保护控制优化建议,并通过调试来验证相关保护定值的合理性,以期提高污泥焚烧系统的运行安全性和可靠性。
Incineration is wildly used for treating sewage sludge because of its considerable reduction in volume.Sludge incineration is complex and involves the safety of equipment,life,and also environment,which make the protection control of the incineration system especially important.The protection control of the bubbling fluidized bed(BFB)boiler in Bailonggang sludge treatment and disposal phaseⅡproject is introduced including analysis of the protection control principle,establishment of serval logic relationship and proposal of some reasonable suggestions.Meanwhile,the reasonability of default values was verified by commissioning,so as to improve the safety and reliability of the sludge incineration system.
作者
应基光
林莉峰
邵钦
YING Ji-guang;LIN Li-feng;SHAO Qin(Shanghai Municipal Engineering Design Institute<Group>Co.Ltd.,Shanghai 200092,China;Shanghai Municipal Sewerage Co.Ltd.,Shanghai 200092,China)
出处
《中国给水排水》
CAS
CSCD
北大核心
2021年第10期133-137,共5页
China Water & Wastewater
基金
上海市国际科技合作基金资助项目(19230730900)。
关键词
污泥焚烧
鼓泡流化床
保护控制
逻辑联锁
sludge incineration
bubbling fluidized bed
protection control
logic interlock