期刊文献+

基于不确定性量化和自适应调试的空调冷却水系统优化设计

Optimal design of air-conditioning cooling water system based on uncertainty quantization and adaptive adjustment
下载PDF
导出
摘要 不确定性问题处理不当容易导致空调水系统选型过大和能源浪费。本文提出基于不确定性量化和自适应调试的空调冷却水系统优化设计方法:在设计阶段,将水系统存在的各种不确定因素进行概率量化,从而获得水泵压头的概率分布,并根据该分布配置合适的水泵方案,在调试阶段,以最小节流实现设计流量为原则,选择最佳的水泵运行方案。通过实际案例分析,对所提方法进行验证,结果表明该方法具有很好的可行性和显著的节能效果。 Improper handling of uncertainty issues can easily lead to excessive selection of air-conditioning water system and energy waste.An optimal design method of air-conditioning cooling water system based on uncertainty quantification and adaptive adjustment is proposed.In the design stage,various uncertain factors in the water system are probabilistic quantified to obtain the probability distribution of the pump head,and according to this distribution,the appropriate water pump scheme is configured;in the adjustment stage,the best water pump operation scheme is selected based on the principle of minimum throttling to achieve the design flow.Through actual case analysis,the proposed method is verified,and the results show that the method has good feasibility and significant energy-saving effect.
作者 曾瑞璇 颜承初 杨秀秀 孙龙飞 徐小平 邓亚宏 Zeng Ruixuan;Yan Chengchu;Yang Xiuxiu;Sun Longfei;Xu Xiaoping;Deng Yahong(Nanjing Tech University;The Second Construction Co.,Ltd.of China Construction Third Engineering Bureau)
出处 《制冷与空调》 2021年第6期75-80,84,共7页 Refrigeration and Air-Conditioning
基金 国家自然科学基金青年基金项目(51708287) 江苏省自然科学基金青年基金项目(BK20171003)。
关键词 空调 冷却水系统 不确定性分析 优化设计 自适应调试 air-conditioning cooling water system uncertainty analysis optimal design adaptive adjustment
  • 相关文献

参考文献9

二级参考文献29

共引文献99

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...