摘要
利用黄家湖1:1岛式上层建筑搭建舰用变风量空调系统,系统完成调试后,分别开展固定新风量运行试验、风量匹配有效性试验、变风量末端装置压力无关特性试验、送风温度控制试验、舱室送风控温效果试验和变风量空调系统整体连续运转试验,进行试验分析并提出建议。
The variable air volume(VAV)naval air conditioning system was built by using 1:1 island superstructure in Huangjiahu test base.After the system is debugged,the operation test of fixed fresh air volume,air volume matching effectiveness test,VAV terminal device pressure independent characteristic test,supply air temperature control test,cabin supply air temperature control effect test and VAV air conditioning system overall continuous operation test were carried out respectively.The test results were analyzed and specific test conclusions were put forward.
作者
张轩
金正涛
李伟光
施红梅
ZHANG Xuan;JIN Zheng-tao;LI Wei-guang;SHI Hong-mei(China Ship Development and Design Center, Wuhan 430064, China)
出处
《船海工程》
北大核心
2021年第S01期109-111,共3页
Ship & Ocean Engineering
关键词
舰用
变风量空调
陆上联调试验
marine
VAV air conditioning
land combined modulation experiment