摘要
样品经过高效智能微波消解法进行前处理,采用石墨炉原子吸收光谱法(AAS)测定考核样大米粉中的镉含量并用电感耦合等离子体质谱法(ICP-MS)进行验证。结果表明,AAS法与ICP-MS法的测定结果虽然没有显著性差异,质控物质的测定值均在不确定度范围内,但使用ICP-MS法测定比AAS法更稳定,测定结果更精确。考核样结果经评价,ICP-MS法Z值为0.1,AAS法Z值为0.4。说明ICP-MS测定方法优于AAS法,采用ICP-MS法测定样品,其消解后不用赶酸,减少污染、检测时间短、安全、高效便捷,尤其能同时检测多种元素且检测范围广。因此,ICP-MS法更适合大批量检测多元素样品,为食品中重金属元素检测提供参考依据。
The samples were pretreated by high-efficient intelligent microwave digestion.The cadmium content in rice flour was determined by graphite furnace atomic absorption spectrometry(AAS)and verified by inductively coupled plasma mass spectrometry(ICP-MS).The results showed that although there was no significant difference between the determination results of AAS method and ICP-MS method,and values of controlled substances were within the uncertainty range.However,ICP-MS method was more stable and more accurate than AAS method.According to sample results,Z value of ICP-MS method was 0.1,and that of AAS method was 0.4.It shows that ICP-MS method is better than AAS method.Using ICP-MS method,samples don’t have to get rid of acid after digestion;the method also reduces the pollution and shorten the detection time.It is safe,efficient and convenient.The method can simultaneously detect a variety of elements in a wide range of detection.Therefore,ICP-MS method is more suitable for detecting multi-element samples in large quantities.The study provides a reference for the detection of heavy metal elements in food.
作者
杨晓忱
YANG Xiaochen(Ningxia Grain and Oil Product Quality Testing Center,Yinchuan 750001)
出处
《中国食品添加剂》
CAS
北大核心
2021年第7期114-121,共8页
China Food Additives
关键词
镉
石墨炉原子吸收法
ICP-MS法
考核样
大米粉
cadmium
graphite furnace atomic absorption spectrometry
ICP-MS
test sample
rice flour