期刊文献+

芬顿流化床COD去除率影响因素研究

Research on Influencing Factors of COD Removal Rate in Fenton Fluidized Bed
下载PDF
导出
摘要 针对芬顿反应参数设置不合理、内部流态不均匀导致COD(化学需氧量(Chemical Oxygen Demand),以化学方法测量水样中需要被氧化的还原性物质的量)去除率不高的问题,通过容器反应条件对COD去除率的影响,确定容器反应的运行条件;优化设计分布管式布水,运用CFD数值模拟的方法进行验证,发现分布管式布水使反应容器内部流化状态均匀无死区,间接使得COD去除率约提升6%。 Aiming at the problem of unreasonable setting of Fenton reaction parameters and uneven internal flow pattern resulting in low COD(Chemical Oxygen Demand)removal rate,determine the operating conditions of the vessel reaction through the influence of vessel reaction conditions on the COD removal rate;Optimize the design of distributed pipe water distribution and use the method of CFD numerical simulation was verified,and it was found that the distributed pipe-type water distribution made the internal fluidization state of the reaction vessel uniform and no dead zone,which indirectly increased the COD removal rate by approximately 6%.
作者 冯国峰 李泽平 高荣 许兆美 FENG Guo-feng;LI Ze-ping;GAO Rong;XU Zhao-mei(Huaiyin Institute of Technology,Huaian Jiangsu 223000,China)
机构地区 淮阴工学院
出处 《装备制造技术》 2021年第5期97-99,共3页 Equipment Manufacturing Technology
基金 “江苏省研究生科研与实践创新计划项目”课题名称:一体化芬顿流化床装置优化设计,项目编号:SJCX21_1506。
关键词 COD去除率 CFD数值模拟 流化状态 COD removal rate CFD numerical simulation fluidization state
  • 相关文献

参考文献4

二级参考文献31

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部