摘要
近年来,随着各城市新建地铁线路的增多,轨道交通运营安全也越来越受到重视。道岔挤岔故障作为影响行车最严重的故障之一,一旦出现故障,如何快速判断故障点及如何迅速处理故障并将影响行车的程度减到最低,成为各地铁公司的一项重要研究课题。文章对如何判断道岔挤岔故障及针对ZDJ9可挤型转辙机一旦道岔出现挤岔故障信号专业如何快速修复方法进行了深入分析。
In recent years,with the increase of new subway lines in various cities,the safety of rail transit operation has been paid more and more attention.Turnout squeezing fault is one of the most serious faults affecting traffic.Once the fault occurs,how to judge the fault point quickly and how to deal with the fault quickly and minimize the impact on traffic has become an important research topic for every subway company.This paper makes an in-depth analysis on how to judge the turnout fault and how to quickly repair the fault signal of ZDJ9 squeezable switch machine.