摘要
介绍了变磁通调压自耦变压器工作原理及关键技术参数,列举了5种变磁通调压自耦变压器典型结构。以单柱和旁柱激磁结构为例,对比介绍恒磁通、变磁通调压冲击性能。
This paper introduces the working principle and key technical parameters of variable flux voltage regulation of autotransformer.Five typical structures of variable flux voltage regulating autotransformer are listed.Taking the excitation structure of single column and side column as an example,the voltage regulating and impact performance of constant flux and variable flux are compared and introduced.
作者
宁澔如
Ning Hao-ru(TBEA Hengyang Transformer Co.,Ltd.,Hengyang 421007,China)
出处
《变压器》
2021年第7期25-28,共4页
Transformer
基金
2021年衡阳市科技计划项目-科技重大项目。
关键词
自耦变压器
变磁通
补偿
冲击
激磁
Autotransformer
Variable flux
Compensation
Impact
Excitation