摘要
针对现有检测动态心电图数据准确性采用手动录入验证方式耗时问题,首先将标准数据库文件转换为模拟量,在不同文件之间设置波特特征比较明显的方波和脉冲作为间隔数据,然后按照数据库文件顺序一次性全部将测试信号自动输出至心电采集设备。最后对采集设备中记录的数据按照间隔数据协议进行分离,从而达到动态心电图的快速数字化检验的目的。
The square waves and pulses with obvious porter characteristics are inserted into each different adjacent existing dynamic electrocardiogram data to solve the time-consuming problem in the currently used manual input verification method.The standard database files are converted into analog siginals,then output automatically to the ECG acquisition device according to the sequence of the database files in one time.The data recorded in the acquisition equipment is separated according to the interval data protocol,so as to achieve the purpose of rapid digital examination of dynamic electrocardiogram.
作者
杨晓玲
韩溟
黎金
YANG Xiaoling;HAN Ming;LI Jin(Shaanxi Medical Device Quality Testing Institute,Xi’an,712046)
出处
《中国医疗器械杂志》
2021年第4期442-445,共4页
Chinese Journal of Medical Instrumentation
基金
2019年西安市第二批科技计划项目(2019216814GXRC-004CG005-GXYD4.0)
2019年陕西省重点研发计划(2019GY-071)。
关键词
动态心电图
数据库
记录
分离
比对
dynamic electrocardiogram
database
record
separate,comparison