摘要
采用电感耦合等离子体发射光谱法测定煤基油品中的Ni、Fe、V元素,对比分析了灰化法和微波消解法的前处理方法,并优化了实验条件,建立了各元素的标准曲线,相关系数均在0.9995以上,加标回收率为98.8%~104.0%,相对标准偏差均小于2%(n=6)。
Inductively coupled plasma atomic emission spectrometry(ICP-AES)was used to determine Ni,Fe and V in coal based oil.Two pretreatment methods,ashing method and microwave digestion method,were compared and studied,and the experimental conditions were optimized.The standard curve of each element was established,and the correlation coefficient was above 0.9995.In the actual sample analysis,the recovery rates of this method range between 98.8%and 104.0%,and the relative standard deviation of repeated determination was less than 2%(n=6).The method is also applied to the determination of standard material,and the result is basically consistent with the value of standard material.
作者
赵静
张坤龙
张生娟
姬鹏军
杨猛
杜宁
石欣
时肖栋
Zhao Jing;Zhang Kunlong;Zhang Shengjuan;Ji Pengjun;Yang Meng;Du Ning;Shi Xin;Shi Xiaodong(Hydrocarbon High-Efficiency Utilization Technology Reserch Center,Shaanxi Yanchang Petroleum(Group)Co.,Ltd.,Xi’an 710075,Shaanxi,China)
出处
《精细石油化工》
CAS
2021年第4期66-69,共4页
Speciality Petrochemicals
关键词
煤基油品
微波消解
金属元素
coal-based oils
microwave digestion
metal elements