期刊文献+

Studies on the spray dried lactose as carrier for dry powder inhalation 被引量:1

下载PDF
导出
摘要 The purpose of this study was to investigate the spray dried lactose as carrier for dry powder inhalation(DPI).The lactose particles were prepared by spray drying,then the particle size,shape and crystal form were characterized by laser diffraction,scanning electron microscopy(SEM),X-ray diffraction(XRD)and differential scanning calorimetry(DSC).The spray dried lactose particles were spherical and amorphous,but would transfer to crystal form when storage humidity was above 32%.Thus,the humidity of the storage environment should be controlled below 30%strictly in order to maintain the amorphous nature of spray dried lactose which is a great benefit to DPI development.
出处 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2014年第6期336-341,共6页 亚洲药物制剂科学(英文)
基金 This work was supported by the National Natural Science Foundation of China(No.:81173002) the National Science and Technology Support Program(No.:2012BAI35B02).
  • 相关文献

参考文献1

二级参考文献156

  • 1Matthew D. Jones,Jennifer C. Hooton,Michelle L. Dawson,Alan R. Ferrie,Robert Price.An Investigation into the Dispersion Mechanisms of Ternary Dry Powder Inhaler Formulations by the Quantification of Interparticulate Forces[J]. Pharmaceutical Research . 2008 (2)
  • 2Desmond Heng,Patricia Tang,Julie M. Cairney,Hak-Kim Chan,David J. Cutler,Rania Salama,Jimmy Yun.Focused-ion-beam Milling: A Novel Approach to Probing the Interior of Particles Used for Inhalation Aerosols[J]. Pharmaceutical Research . 2007 (9)
  • 3Matthew S. Coates,Hak-Kim Chan,David F. Fletcher,Herbert Chiou.Influence of Mouthpiece Geometry on the Aerosol Delivery Performance of a Dry Powder Inhaler[J]. Pharmaceutical Research . 2007 (8)
  • 4Albert H. L. Chow,Henry H. Y. Tong,Pratibhash Chattopadhyay,Boris Y. Shekunov.Particle Engineering for Pulmonary Drug Delivery[J]. Pharmaceutical Research . 2007 (3)
  • 5Gary P. Martin,Christopher Marriott,Xian-Ming Zeng.Influence of Realistic Inspiratory Flow Profiles on Fine Particle Fractions of Dry Powder Aerosol Formulations[J]. Pharmaceutical Research . 2007 (2)
  • 6Matthew D. Jones,Robert Price.The Influence of Fine Excipient Particles on the Performance of Carrier-Based Dry Powder Inhalation Formulations[J]. Pharmaceutical Research . 2006 (8)
  • 7Matthew S. Coates,Hak-Kim Chan,David F. Fletcher,Judy A. Raper.Influence of Air Flow on the Performance of a Dry Powder Inhaler Using Computational and Experimental Analyses[J]. Pharmaceutical Research . 2005 (9)
  • 8Matthew S. Coates,David F. Fletcher,Hak-Kim Chan,Judy A. Raper.The Role of Capsule on the Performance of a Dry Powder Inhaler Using Computational and Experimental Analyses[J]. Pharmaceutical Research . 2005 (6)
  • 9Nora Y. K. Chew,Patricia Tang,Hak-Kim Chan,Judy A. Raper.How Much Particle Surface Corrugation Is Sufficient to Improve Aerosol Performance of Powders?[J]. Pharmaceutical Research . 2005 (1)
  • 10Philippe Begat,David A.V. Morton,John N. Staniforth,Robert Price.The Cohesive-Adhesive Balances in Dry Powder Inhaler Formulations I: Direct Quantification by Atomic Force Microscopy[J]. Pharmaceutical Research . 2004 (9)

共引文献8

同被引文献5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部