摘要 本文从气体绝缘金属封闭开关设备元器件的布局、电极形状的改变、均压环(屏蔽环)的使用、接地屏蔽网的设置、结构设计改进五个方面对气体绝缘金属封闭开关设备在电场均匀方面采取的措施进行了分析,在产品的设计和工程应用中,可提升设备整体的绝缘能力,保证设备安全可靠的运行。 This article focuses on the five aspects of gas-insulated metal-enclosed switchgear components:layout of gas-insulated metal-enclosed switchgear components,changes in electrode shape,use of equalizing rings(shielding rings),setting of grounding shielding nets,and structural design improvements.The measures taken in terms of electric field uniformity are analyzed.In product design and engineering applications,the overall insulation capacity of the equipment can be improved to ensure the safe and reliable operation of the equipment.
作者 李元鹏 崔鹏 LI Yuan-peng;CUI Peng(Guangzhou Baiyun Electric Equipment Co.,Ltd.,Guangzhou 510460,China)
出处 《价值工程》 2021年第22期135-137,共3页 Value Engineering
关键词 气体绝缘金属封闭开关设备 电场 电极形状 均压环 接地屏蔽网 gas-insulated metal-enclosed switchgear electric field electrode shape equalizing ring grounding shielding network