摘要
We present the experimental study of modulation transfer spectroscopy of ytterbium atoms in a hollow cathode lamp.The dependences of its linewidth,slope and magnitude on the various experimental parameters are measured and fitted by the well-known theoretical expressions.The experimental results are in good agreement with the theoretical prediction.We have observed the Dicke narrowing effect by increasing the current of the hollow cathode lamp.It is also found that there are the optimal current and laser power to generate the better modulation transfer spectroscopy signal,which can be employed for locking the laser frequency to the atomic transition.
作者
WANG Wen-Li
XU Xin-Ye
王文丽;徐信业(State Key Laboratory of Precision Spectroscopy and Department of Physics,East China Normal University,Shanghai 200062)
基金
Supported by the National Natural Science Foundation of China under Grant No 10774044
the National Key Basic Research Program of China under Grant No 2010CB922903
Shanghai Pujiang Talent Program under Grant No 07PJ14038.