摘要
Traditionally,shock temperature determination of metals needs to do a two-step calculation from the measured thermal radiation history.In this paper,however,we present some experimental events which make it possible to deduce the release temperature directly from the measured interface radiation history record.
基金
Supported by and performed at the Laboratory for Shock Wave and Detonation Physics Research,Southwest Institute of Fluid Physics.