摘要 本文对元素分析—稳定同位素比值质谱联用仪(EA-IRMS)进行改装,并利用其测定不同形态硫同位素标准物质和样品。结果表明,在色谱柱后加装SO_(2)气体捕集管,可捕集氧化还原产生的SO_(2)气体,并重复调用作为参考气使用,无需外部引入高纯SO_(2)气体,减小了其对仪器管路腐蚀和实验室环境危害;硫酸钡进样量约400μg时,捕集管中的SO_(2)气体可提供至少20次峰中心聚焦;改装后的EA-IRMS系统测试硫同位素标准物质(IAEA-SO-5、IAEA-S-2、IAEA-S-3、EMA-P1),当硫元素进样量为20μg时,δ^(34)S值测试精度达到0.2‰(n=3),4种国际标准物质测量值与真实值相关系数良好(R^(2)=1),表明硫的不同化合物δ^(34) S值可以相互校准,也表明EA-IRMS改装后可以满足硫同位素测试精度的要求。 In this paper,the elemental analysis-stable isotope ratio mass spectrometer(EA-IRMS)is modified to testing different forms of sulfur isotope standard material and sample.A SO_(2)gas trap tube is installed after chromatographic column to trap the SO_(2)gas generated by redox reaction and the captured SO_(2)can be used as reference gas several times,there is no need to introduce high-purity SO_(2)gas externally,which reduces the damage to the instrument pipeline corrosion and laboratory environment.When the amount of barium sulfate is about 400μg,SO_(2)gas in the trap tube can provide at least 20 peak center focus.Modified EA-IRMS system testing sulfur isotope standard material(IAEA-SO-5,IAEA-S-2,IAEA-S-3,EMA-P1),when the sulfur element injection volume is 20μg,the δ^(34) S value test accuracy achieve 0.2‰(n=3),4 kinds of international standard material measured value and true value have a good correlation coefficient(R^(2)=1),it indicates that the δ^(34) S value of different compounds of sulfur can be mutual calibration,and the modified EA-IRMS can meet the accuracy requirement of the sulfur isotope test.
作者 尹希杰 王永涛 刘维维 苏静 YIN Xijie;WANG Yongtao;LIU Weiwei;SU Jing(Information and Testing Support Center,Third Institute of Oceanography,Ministry of Natural Resources,Xia Men 361005,China;School of Resources&Environment,Henan Polytechnic University,Jiaozuo 454000,China)
出处 《同位素》 CAS 2021年第4期325-331,I0001,共8页 Journal of Isotopes
基金 国家自然科学基金项目(91858208,41976050)。
关键词 元素分析—稳定同位素比值质谱联用仪 二氧化硫气体捕集 硫同位素测定 elemental analysis-sable isotope ratio mass spectrometer SO_(2)gas trapping determination ofδ34 S value
  • 相关文献

参考文献8

二级参考文献63

共引文献76

同被引文献47

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部