摘要 目的分析改良关节突截骨技术在椎间孔镜下治疗腰椎管狭窄症(PELD)的临床疗效及手术技巧。方法选取我院自2018年2月至2020年9月间根管狭窄型腰椎管狭窄症患者46例,其中男26例,女20例,年龄42~73岁,平均(56±7.1)岁。术前定位将1枚2.0 mm克氏针作为导针滑入椎间孔内,应用克氏针调节器固定针根据临床需要向背侧调节后,应用6.3 mm环锯做关节突截骨并进行手术。结果所有患者均顺利完成手术,手术时间平均(50.32±10.54)min,术中透视次数平均为(5.00±2.14)次。所有患者平均随访时间8.23个月(6~15个月)。术后各时间点VAS评分及ODI评分较术前均有显著改善,差异有统计学意义(P<0.001)。结论PELD术中应用克氏针调节器辅助一次关节突成形技术,在缩短手术定位时间的同时,减少了放射暴露,取得了良好的治疗效果,适合临床推广应用。
出处 《内蒙古医学杂志》 2021年第8期986-988,F0004,共4页 Inner Mongolia Medical Journal
  • 相关文献

参考文献5

二级参考文献50

  • 1Ahn Y. Transforaminal percutaneous endoscopic lumbar dis- cectomy: technic tips to prevent complications[J]. Expert Rev Med Devices, 2012, 9(4): 361-366.
  • 2Ahn Y. Percutaneous endoscopic decompression for lumbar spinal stenosis [J]. Expert Rev Med Devices, 2014, 11 (6): 605 -616.
  • 3Nellensteijn J, Ostelo R, Bartels R, et al. Transforaminal en- doscopic surgery for symptomatic lumbar disc herniations: a systematic review of the literature[Jl. Eur Spine J, 2010, 19 (2): 181-204.
  • 4Fan G, Guan X, Zhang H, et al. Significant improvement of puncture accuracy and fluoroscopy reduction in percutaneous transforaminal endoscopic eiscectomy with novel lumbar loca- tion system: preliminary report of prospective hello study [J]. Medicine (Baltimore), 2015, 94(49): e2189.
  • 5Fan G, Fu Q, Gu G, et al. Radiation exposure to surgeon in minimally invasive transforaminal lumbar interbody fusion with novel spinal locators[J]. J Spinal Disord Tech, 2015, 28 (3): E173-180.
  • 6Gu G, Zhang H, He S, et al. Percutaneous pedicle screw placement in lumbar spine: a comparison study between the novel guidance system and the conventional fluoroscopy method[J]. ] Spinal Disord Tech, 2013, 26(7): E277-280.
  • 7Gu G, Zhang H, He S, et al. Preoperative localization meth- ods for minimally invasive surgery in lumbar spine: compar- isons between a novel method and conventional methods[J]. J Spinal Disord Tech, 2013, 26(7): E277-280.
  • 8Zhang L, Zhou X, Cai X, et al. Reduction in radiation dur- ing percutaneous lumbar pedicle screw placement using a new device[J]. Minim Invasive Ther Allied Technol, 2014, 23(3): 173-178.
  • 9Fan G, He S and Chert Z. Musculoskeletal pain and cancer risk of staff working with fluoroscopically guided procedures [J]. J Am Co11 Cardiol, 2015, 66(6): 759-760.
  • 10Fan G, Fu Q, Zhang H, et al. Direct-beam radiation expo- sure to surgeons during pinning of supracondylar humerus fractures[J]. J Pediatr Orthop, 2015, 35(4): e37.

共引文献280

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部