摘要 Abnormal voltages such as electrostatic,constant current,and strong electromagnetic signals can erroneously trigger operation of MEMS pyrotechnics and control systems in a fuze,which may result in casualties.This study designs a solid-state micro-scale switch by combining the corona gas discharge theory of asymmetric electric fields and Peek’s Law.The MEMS switch can be transferred from“off”to“on”through the gas breakdown between the corona electrodes.In the model,one of the two electrodes is spherical and the other flat,so a non-uniform electric field is formed around the electrodes.The theoretical work is as follows.First,the relation among the radius of curvature of the spherical electrode,the discharge gap,and the air breakdown voltage is obtained;to meet the low voltage(30-60 V)required to drive the MEMS switch,the radius of curvature of the spherical electrode needs to be 10 e50 mm and the discharge gap between the two electrodes needs to be 9e11 mm.Second,the optimal ratioεis introduced to parameterize the model.Finally,the corona discharge structural parameters are determined by comparing the theoretical and electric field simulation results.The switch is then fabricated via MEMS processing.A hardware test platform is built and the performing chip tested.It is found that when the electrode gap is 9 mm,the electrostatic voltage is at least 37.3 V,with an error of 2.6%between the actual and theoretical air breakdown voltages.When the electrode gap is 11 mm,the electrostatic voltage is at least 42.3 V,with an error of 10.5%between the actual and theoretical air breakdown voltages.Both cases meet the design requirements.
出处 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2021年第4期1453-1460,共8页 Defence Technology
  • 相关文献

参考文献2

二级参考文献16

  • 1WILSON P F, MA MT. Field Radiated by Elec- trostatic Discharges[J]. IEEE Transactions on Elec- tromagnetic Compatibility (EMC), 1991, 33(1): 10-18.
  • 2HONDA M. Indirect ESD Measurement Using a Short Monopole Antenna[ClII Proceedings of 1990 IEEE International Symposium on Elec- tromagnetic Compatibility: August 21-23, 1990. Washington, DC, USA, 1990: 641-645.
  • 3MACLEOD L M, BALMAlN K G Compact Trave- ling-Wave Physical Simulator for Human ESD [J]. IEEE Transactions on Electromagnetic Com- patibility, 1997, 39(2): 89-99.
  • 4POMMERENKE D. ESD: Transient Fields, Arc Simulation and Rise Time Limit[J]. Journal of Electrostatics, 1995,36(1): 31-54.
  • 5ZARIDZE R, KARKASHADZE D, DJOBAVA R G, et a/. Numerical Calculation and Measurement of Transient Fields from Electrostatic Disch- arge[J]. IEEE Transactions on Components, Pack- aging, and Manufacturing Technology, Part C, 1996, 19(3): 178-183.
  • 6FUJIWARA 0, An Analytical Approach to Mo- del Indirect Effect Caused by Electrostatic Dis- charge[J]. IEICE Transactions on Communica- tions, 1996, E-79-B(4).
  • 7ISHIGAMI S, GOKITA R, NISHIYAMA Y, et al. Measurements of Fast Transient Fields in the Vicinity of Short Gap Discharges[J]. IEICE Tran- sactions on Communications, 1995, E78-B(2): 199-206.
  • 8KAWAMATA K, MINEGISHI S, HAGA A, et al. 12 GHz Real Time Measurement of Voltage Rise Time and Current Rise Time Due to Micro Gap Discharge in Voltage Below 1 kV[C]// Proc- eedings of International Symposium on Electro- magnetic Compatibility: September 4-8, 2006. Barcelona, Spain, 2006: 107-110.
  • 9KAWAMATA K, MINEGISHI S, HAGA A, et al. 12 GHz Measurement of Transition Duration and Breakdown Field Due to Low Voltage ESD [C]II Proceedings of 18th International Zurich Symposium on Electromagnetic Compatibility (EMC): September 24-28, 2007. Munich, Ger- many, 2007: 225-228.
  • 10KAWAMATA K, MINEGISHI S, HAGA A, et al. Measurement of Voltage and Current Wave- forms Using 12 GHz Measurement System and Breakdown Field Strength due to Micro Gap Discharge[J]. IEICE Transactions on Commun- ications, 2007, J90-B(11): 1143-1148 (in Jap- anese).