摘要 为提高核仪表系统计算中子注量率、中子变化率的准确性,通过分析传统V/F转换电路与I/F转换电路的工作原理及特性,介绍了一种基于I/F理论的核仪表系统设计方案,并进行实验。实验结果表明:将I/F转换技术应用于核仪表系统具备一定可行性,且测量误差在允许范围内,与传统V/F转换方式相比,I/F转换具有更好的线性。 In order to improve the accuracy of calculating neutron flux rate and neutron change rate of nuclear instrument,analyzing the working principle and characteristics of V/F conversion circuit、I/F conversion circuit introduces a design scheme of nuclear instrument based on I/F theory.The experimental results show that it is feasible to apply I/F conversion technology to nuclear instrument,and the error is within the allowable range.Compared with the V/F conversion mode,I/F conversion has better linearity.
作者 贾艺歌 杨诚 李昂 李丹 韩文兴 吴志强 JIA Yi-ge;YANG Cheng;LI Ang;LI Dan;HAN Wen-xing;WU Zhi-qiang(Nuclear Power Institute Of China,Scienceand Technologyon Reactor System Design Technology Key Laboratory,Chengdu 610213,China)
出处 《核电子学与探测技术》 CAS 北大核心 2021年第1期98-102,共5页 Nuclear Electronics & Detection Technology
基金 中国核动力研究设计院青年基金。
关键词 核仪表 微电流放大 V/F转换 I/F转换 Nuclear Instrument Micro-current Amplification V/F Conversion I/F Conversion
  • 相关文献

参考文献3

二级参考文献18

  • 1王超,许化龙.基于I/F变换的高精度数据采集方案分析[C]//2007年全国测量、计量仪器、仪表学术年会,2007:386.390.
  • 2清华大学.射线仪器电子学(上册)[M].北京:原子能出版社,..
  • 3PATTERSON G E, GUYMON A J, RITER L S, et al.. Miniature cylindrical ion trap mass spectrometer[J]. Analytical Chemistry, 2002, 74(24): 6145-6153.
  • 4FRANCO S. Design With Operational Amplifiers and Analog Integrated Circuits [M].3rd ed. San Francisco: McGraw-Hill, 2001: 310-353.
  • 5KIM D J, KOO J Y. A low-noise and wide-band ac boosting current-to-voltage amplifier for scanning tunneling microscopy [J].Review of Scientific Instruments, 2005, 76(2) : 023703-1-4.
  • 6KALTHOFF T, WANG T, STITT R M. Classical op amp or current-feedback op amp? This composite op amp gives you the best of both worlds [Z]. Burr-Brown Application Bulletin, 1991.
  • 7ACHARYA Y B. Current conveyor based electrometer [J]. AEU- International Journal of Electronics and Communications, 2005, 59(7): 413-416.
  • 8HIGA H, IWAKI J, NAKAMURA I. A basic study on noise source modeling for a very low-level DC current amplifier [J].IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences, 2005, E88-A (6) :1401-1407.
  • 9WRIGHT P, OZANYAN K B, CAREY S J, et al.. Design of high performance photodiode receives for optical tomography [J]. IEEE Sensors Journal, 2005, 5(2) : 281-288.
  • 10GRAEME J G. Photodiode Amplifiers-Op Amp Solutions [M]. New York: McGraw-Hill, 1995: 107-128.