摘要 针对超高层建筑消防给水系统的不同分区形式.提出了对消防给水系统分区的评估和评价的问题。超高层建筑消防给水系统分区的评价有利于解决系统分区形式,从定性与定量的角度给出评价的结果.建立了基于可靠性为基础的分区形式系统评价方法。消防给水分区的系统评价包括直接评定和综合评定的评定方法。直接评价对存在重大隐患的设计进行对标评定。综合评定可以采用不同的指标进行多因素的评估,提出了评估的指标,并给出了系统组件可靠度的计算方法。 Aiming at different division of fire water supply in super high-rise buildings,it is established the evaluation method of fire water supply division based on the reliability.The evaluation of fire water supply system is helpful to the evaluation of the system partition form in super high-rise building.The evaluation result is given from the qualitative and quantitative perspectives.The system evaluation of fire water supply zone includes the direct evaluation and comprehensive e-valuation.The direct evaluation is evaluated to the significant hidden danger of design.The comprehensive evaluation can use different indexes to evaluate multi-factors,and the evaluation indexes are proposed,and the calculation method of system component reliability is given.
作者 杨琦 YANG Qi(East China Architectural Design&Research Institute,Shanghai 200002,China;Shanghai Engineering Research Center of Super High-Rise Building Design,Shanghai 200002,China)
出处 《给水排水》 CSCD 北大核心 2021年第8期120-124,共5页 Water & Wastewater Engineering
基金 “上海超高层建筑设计工程技术研究中心”建设项目(14DZ2252800)。
关键词 消防给水分区 评价体系 超高层建筑 可靠性 分区评估 Fire water supply division Evaluation system Super high-rise building Reliability Division evaluation