期刊文献+

电力变压器局部放电带电检测及定位技术研究 被引量:1

Research on Live Detection and Location Technology of Partial Discharge in Power Transformer
下载PDF
导出
摘要 为了探讨电力变压器局部放电时的带电检测方法及定位技术要点,结合相关经验,分别探讨了局部放电带电检测技术和电力变压器局部放电带电定位技术,最终给出技术要点和带电检测方法。通过分析可知,带电检测及定位技术可以有效地提高电力系统维护工作效率和提高电力服务稳定性。 In order to explore the power transformer partial discharge live detection method and positioning technology points,combined with the author's work experience,this paper discusses the partial discharge live detection technology and power transformer partial discharge live positioning technology,and finally gives the technical points and live detection method.Through the analysis,live detection and positioning technology can effectively improve the efficiency of power system maintenance and improve the stability of power service.
作者 艾澎 Ai Peng
出处 《电力系统装备》 2021年第15期50-51,共2页 Electric Power System Equipment
关键词 电力变压器 局部放电 带电检测 定位技术 power transformer partial discharge live detection positioning technology