在对航天器敏感材料开展高加速紫外模拟试验的过程中,需要对近紫外辐照模拟的均匀性进行控制,以提高试验模拟的有效性和试验结果的准确性。文章采用氙灯作为紫外辐照源,利用聚光镜、光学积分器和反射/滤光镜,实现了大面积高均匀度的紫外辐照;同时,利用准直镜和发散镜的设计,成功兼顾高加速倍率和较大辐照面积,可实现ϕ300 mm面积上紫外辐照度为15SC、ϕ180 mm面积上紫外辐照度为24SC、均匀性均优于95%的紫外模拟。
In the highly accelerated near ultraviolet(NUV)irradiation simulation tests on the vulnerable materials for spacecraft,it is essential to control the uniformity of the NUV irradiation to improve the effectiveness of the test simulation and the accuracy of the test results.In this paper,the Xenon lamp is used as the NUV irradiation source,while the condenser,the integrator,and the reflector or the filter are used to realize a highly accelerated NUV irradiation with quite good uniformity.At the same time,the collimating mirror and the divergent mirror are designed to realize a high acceleration rate on a suitable large irradiation area.The NUV simulation with an irradiance of 15SC on an area ofϕ300 mm,or an irradiance of 24SC on an area ofϕ180 mm can be realized,with a uniformity better than 95%.
作者
杨艳斌
沈自才
张鹏嵩
李竑松
姜利祥
贺洪波
王胭脂
邵建达
YANG Yanbin;SHEN Zicai;ZHANG Pengsong;LI Hongsong;JIANG Lixiang;HE Hongbo;WANG Yanzhi;SHAO Jianda(Beijing Institute of Spacecraft Environment Engineering,Beijing 100094,China;Shanghai Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,Shanghai 201800,China)
出处
《航天器环境工程》
北大核心
2021年第4期435-439,共5页
Spacecraft Environment Engineering
基金
国家自然科学基金项目(编号:11975052,11904376)
国家重点研发计划项目(编号:2018YFE0118000)。
关键词
近紫外辐照
高加速倍率
模拟试验
辐照均匀性
near ultraviolet irradiation
high acceleration factor
simulation test
radiation uniformity