期刊文献+

双膜处理技术应用存在的问题及注意事项 被引量:3

Problems existing in application of double membrane treatment technology and matters needing attention
下载PDF
导出
摘要 对双膜处理技术在水处理领域易出现的问题进行归类分析、总结和评价,提出生产过程中的注意事项和评价方法,发挥双膜处理技术优势,提供科学管理方法和污染物控制措施。为保证双膜系统正常运行,在做好原水指标控制同时,关注双膜系统的流量、压力、压差的变化,以保证双膜系统在可控的工艺指标运行,实现科学管理和污染物得到有效控制的目的。 This paper conducted the classification,analysis,summarization and evaluation on the problems that were likely to occur in the field of water treatment with double membrane treatment technology,put forward the matters for attention and evaluation methods in the production process in advance,gave full play to the advantages of double membrane treatment technology,and pro⁃vided scientific management methods and pollutant control measures.In order to ensure the normal operation of the double mem⁃brane system,we should pay attention to the changes of the flow rate,pressure and differential pressure of the double membrane sys⁃tem while controlling the raw water index,so as to ensure the operation of the double membrane system under the controllable tech⁃nical index and realize the purpose of scientific management and effective control of pollutants.
作者 邢广仁 Xing Guangren(PetroChina Daqing Petrochemical Company Refinery,Daqing 163711,China)
出处 《炼油与化工》 CAS 2021年第4期69-70,共2页 Refining And Chemical Industry
关键词 超滤膜 反渗透膜 膜元件 污染物 ultrafiltration membrane reverse osmosis membrane membrane elements pollutant
  • 相关文献

参考文献5

二级参考文献59

  • 1左金龙,崔福义,杨威,王欢,张海龙.膜生物反应器处理低温低浊水的工艺研究[J].环境科学,2007,28(2):377-381. 被引量:11
  • 2许嘉炯,郑毓佩,沈裘昌,雷挺,陈宝书,芮旻.新型中置式高密度沉淀池的开发与应用[J].给水排水,2007,33(2):19-24. 被引量:29
  • 3许建华 刘辉 张东.微污染水源水生物预处理及后续工艺的生化延伸效应除污染研究[J].给水排水,2002,(7):1-5.
  • 4Cech I, Montera J.Spatial variations in total aluminum concentrations in drinking water supplies studied by geographic; information system (GIS) methods[J].Water Research,2000,34(10):2703-2712.
  • 5DengShubo, QiuZhou, Yu Gang, et al. Removal ofperfluorooctanoate from surface water by polyaluminium chloridecoagulation [J]. Water Research,2011,45(4): 1774-1780.
  • 6Li Zhong, Zhong Shall, et al. Production of a novel bioflocculant by Bacillus licheniformis X14 and its application to low temperature drinking water treatment [J].Bioresource Technology,2009,100(14): 3650-6.
  • 7Connie Walden, et al. Preliminary assessment of bacterial community change impacted by chlorine dioxide in a water treatment plant[J]. Joumal of Environmental Engineering,2015,142(2):474-478.
  • 8Krasner S W, Weinberg H S, Richardson S D, et al. Occurrence of a new generation of disinfection byproducts [J].Environmental Science & Technology,2006,40:7175-7185.
  • 9Darryl B Jones, Hocheol Song, Tanju Karanfil. The effects of selected preoxidation strategies on I-THM formation and speciation [J].Water Research,2012,46:5491-5498.
  • 10Huanga C, Lin J, Lee W, et al. Effect of coagulation mechanism on membrane permeability in coagulationassisted microfiltration for spent filter backwash water recycling [J]. Colloids and Surfaces A: Physicochemical and Engineering Aspects,2011,378 (1-3):72-78.