TEM室法环天线校准系统建立及测量结果不确定度评定 被引量:6

The Loop Antenna Calibration System Using the TEM Method and the Uncertainty Estimation for the Measurement Results
下载PDF
导出
摘要 横电磁波室法是9 kHz~30 MHz频段环天线校准中广泛采用的一种方法。环天线分为有源环天线和无源环天线两类,这两种天线的磁场天线系数在量值范围上差别大,对系统动态范围要求不同。根据这一特点,对两类环天线分别建立横电磁波室作为标准场的环天线校准系统,基于网络分析仪开展扫频测量。针对电磁兼容领域中常用的直径60 cm以下有源和无源环天线分别开展校准方法研究,给出磁场天线系数测量结果和测量结果的不确定度评定。该环天线校准系统可以扫频完成常用环天线在9 kHz~30 MHz频段内的校准,解决大动态范围问题,环天线校准效率也得到提高。 The transverse electromagnetic(TEM)cell method is widely used in the loop antenna calibrations.The system dynamic range requirement for the active loop and the passive loop are different due to the magnetic antenna factor difference.Two new loop antenna calibration systems based on the TEM cell as the standard field generator have been proposed considering the magnetic field antenna factor difference for active and passive loop respectively,which enable the sweep-frequency measurement.The calibration methods are discussed,the measured magnetic field antenna factors are presented,and the uncertainties are evaluated for the active loop and the passive loop of no more than 60 cm diameter which is normally used in the electromagnetic compatibility(EMC)field,respectively.The sweep-frequency measurements covering from 9 kHz to 30 MHz for the commonly used loop antennas can solve the problem due to the big dynamic range,and also enhance the calibration efficiency.
作者 刘潇 吴艳丽 秦瑶 孟东林 黄攀 LIU Xiao;WU Yan-li;QIN Yao;MENG Dong-Lin;HUANG Pan(National Institute of Metrology,Beijing,100029,China;College of Information Science and Technology,Henan University of Technology,Zhengzhou,Henan 450000,China)
出处 《计量学报》 CSCD 北大核心 2021年第8期1061-1067,共7页 Acta Metrologica Sinica
基金 国家重点研发计划(2018YFF0212102)。
关键词 计量学 横电磁波室 环天线 校准系统 测量不确定度 metrology TEM cell loop antenna calibration system uncertainty
  • 相关文献

参考文献2

二级参考文献11

  • 1JJFl059-1999.测量不确定度评定与表示[s].[S].,..
  • 2Myron L C. Generation of standard EM fields using TEM transmission ceils [ J ]. IEEE Transactions on Electromagnetic Compatibility, 1974,16 (4) : 189 - 195.
  • 3Heinrich Garn. 3_ Comparison of Electric Field-Strength Standards for the Frequency Range of 30-1000MHz [ J ]. IEEE Transaction on Electromagnetic Compatibility, 1997,39(4) :397 -403.
  • 4IEEE Electromagnetic Compatibility Society. IEEE Std. 1309TM--2005 IEEE standard for calibration of electromagnetic field sensors and probes, excluding antennas, from 9 kHz to 40 GHz[ S].
  • 5Matloubi K. A method for calibration of isotropic, E-field probes [ C ]//IEEE 1999 International Symposium Record on Electromagnetic Compatibility, New Jersey, 1991.
  • 6Zilberti L, Bottauseio O, Chiampi M, et al. On the use of TEM cells for the calibration of power frequency electric field meters [ J ]. Measurement, 2010, 43 ( 9 ) : 1282 - 1290.
  • 7Liu X, Xie M, Li D B, et al. A method to calculate the net power delivered into a TEM cell using a directional coupler in a probe calibration application [ C ]//2nd Internationl conference on Sensors, Measurement and Intelligent Materials, Guangzhou, 2013.
  • 8Spiegel R J, Joines W T, Blackman C F, et al. A method for calculating electric and magnetic fields in TEM cells at ELF [ J ]. IEEE Transaction on Electromagnetic Compatibility, 1987, 29(4) : 265 - 272.
  • 9曾嵘,沈晓丽,陈未远.横电磁波小室校准系统产生标准电场的不确定度评定[J].高电压技术,2012,38(11):2781-2788. 被引量:10
  • 10陈锦,刘小龙,燕有杰,李鹏辉,蒋廷勇.小型短电磁脉冲传感器[J].强激光与粒子束,2012,24(12):2797-2801. 被引量:8