期刊文献+

一台引风机的振动问题分析及处理 被引量:5

Vibration Analysis and Treatment of An Induced Draft Fan
下载PDF
导出
摘要 对一台引风机的振动故障进行了分析及处理,其中涉及引风机滚动轴承故障、电动机磁力中心线不对中故障、联轴器止口磨损引起的轴系不对中故障三种故障类型,进行故障排查分析,本文对故障分析进行了较详细的阐述及说明,有助于指导现场的分析判断及检修处理工作。 The vibration fault of an induced draft fan is analyzed and dealt with.There are three kinds of fault types,including induced draft fan rolling bearing fault,motor magnetism centerline misalignment fault,shaft misalignment caused by coupling seam allowance wear is analyzed,This paper gives a more detailed description and explanation of the fault analysis,which gives the guide for analysis,judgment and maintenance work on site.
作者 何小锋 沈景 卢修连 刘晓锋 何利鹏 马运翔 Xiao-feng He;Jing Shen;Xiu-lian Lu;Xiao-feng Liu;Li-peng He;Yun-xiang Ma(Jiangsu Frontier Electric Technologies Co.,Ltd.;Jiangsu Huaiyin Power Generation Co.,Ltd.)
出处 《风机技术》 2021年第S01期63-66,共4页 Chinese Journal of Turbomachinery
关键词 引风机 轴承故障 不对中 止口 磁力中心线 振动 Induced Draft Fan Bearing Failure Misalignment Stop Magnetic Center Line Vibration
  • 相关文献

参考文献9

二级参考文献49

共引文献34

同被引文献34

引证文献5

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部