摘要
摘本实验比较了酶免疫分析法与高分辨气/质法测定土壤和沉物样品中二恶英等价毒性当量(I-TEQ)。实验结果表明:高分辨气/质法优点是可以分离二恶英类每种成分,并能准确定量;缺点是成本高,要求有精密的仪器、多种标准品、良好的实验环境和训练有素的操作人员。酶免疫分析法优点是成本低,操作简单快速;缺点是不能检测二恶英类各个成分。
In this study, enzyme immunoassay and high resolution gas chromatography/mass spectrometry were used to determine the equivalent toxic equivalent(I-TEQ) of dioxins in soil and sediment samples. The experimental results show that the advantages of high-resolution GC/MS method are that each component of dioxins can be separated and quantified accurately;the disadvantages are high cost, requiring precise instruments, a variety of standards, good experimental environment and well-trained operators. However, the advantages of enzyme immunoassay(EIA)are low cost, simple and fast operation;the disadvantages are that it can not detect all components of dioxins.
作者
谭曜
许赛慧
谢建敏
钟莺莺
应海松
曹国洲
Tan Yao;Xu Shaihui;Xie Jianmin;Zhong Yingying;Ying Haisong;Cao Guozhou(Ningbo CustomsTechnology Center,Ningbo 315012,China)
出处
《广东化工》
CAS
2021年第13期198-199,194,共3页
Guangdong Chemical Industry
基金
宁波中盛公司科技计划项目(2020ZS008)。