摘要
集装箱船为传统的三大主力船型之一,一般为尾机型,烟囱与上建一体,因此A-60级防火分隔较多。本文根据SOLAS要求,对集装箱船耐火完整性的实施方案进行探讨,结合隔热延伸需求,选取完善、高效的防火节点。
As one of the three main traditional ship types,it is generally stern-engined typechimney and superstructure are integrated,so there are many A-60 class fire divisions.In this paper,according to the requirements of SOLAS,the specific implementation scheme of fire integrity is discussed.Combined with the requirement of heat insulation elongation more perfect and efficient fire protection node is selected.
作者
梁涓华
梁俊民
刘正亮
LIANG Juanhua;LIANG Junmin;LIU Zhengliang(CSSC Huangpu Wenchong Shipbuilding Co.,Ltd.,Guangzhou 511462)
出处
《广东造船》
2021年第4期83-86,共4页
Guangdong shipbuilding
关键词
集装箱船
防火
隔热延伸
Container ship
Fire protection
Heat insulation elongation