期刊文献+

走航式ADCP在水文站的应用分析 被引量:2

Analysis of Application of Navigational ADCP in Hydrographic Station
下载PDF
导出
摘要 水文站是人类社会对于水环境探索与水资源保护领域不可缺少的重要组成部分,水文站资料的收集与分析需要通过水文仪器设备测量来完成,而走航式ADCP作为信息化时代下的高精度测量仪器,其本身不仅在精度方面有着极为显著的优势,同时还能够有效提升最终测量成果的有效性与真实性,并且确保整个工作效率能够得到较为有效的提升,可以说,在21世纪的今天,走航式ADCP对于水文站测验工作而言所起到的作用是十分巨大的。正因如此,本文就当前我国水文站的基本情况进行概述,并以此为基础提出走航式ADCP在水文站中应用。 Hydrological station is human society for the exploration of water environment and water resources protection of the indispensable important component of hydrologic data collection and analysis needs to be done by hydrological instruments measurement,and walk navigation type ADCP as high precision measuring instruments in the information age,its itself has very significant advantages in terms of accuracy,At the same time,it can effectively improve the validity and authenticity of the final measurement results,and ensure that the entire work efficiency can be effectively improved.It can be said that,in the 21st century,navigational ADCP plays a huge role in the hydrology station test work.For this reason,this paper summarizes the basic situation of hydrographic stations in China,and puts forward the application of navigational ADCP in hydrographic sta⁃tions.
作者 朱宇 李畅 杨丹阳 ZHU Yu;LI Chang;YANG Danyang(Enshi Hydrology andWater Resources Survey Bureau Enshi,Hubei 445000)
出处 《现代农业研究》 2021年第9期153-154,共2页 Modern Agriculture Research
关键词 走航式ADCP 水文站 水文流量 navigational ADCP hydrological station hydrological flow
  • 相关文献

参考文献4

二级参考文献24

  • 1陈学林.声学多谱勒流速剖面仪流量测验精度分析[J].人民黄河,2005,27(7):12-14. 被引量:8
  • 2黄河宁.ADCP流量测验随机误差分析Ⅰ:随机不确定度预测模型[J].水利学报,2006,37(5):619-624. 被引量:11
  • 3席占平,弓增喜,郭相秦,相严,兆兰.ADCP在宽浅河道流量测验中使用小单元尺寸的探讨[J].中国农村水利水电,2006(11):57-59. 被引量:5
  • 4黄河宁.ADCP河流流量测验原理和方法[A].声学多普勒测流原理及其应用[C].郑州:黄河水利出版社,2003.181-206.
  • 5SL337-2006,声学多普勒流量测验规范[S].
  • 6JJF1059.1-2012,测量不确定度评定与表示[S].北京:国家质量监督检验检疫总局,2011.
  • 7Chfistensen, J. L., Herrick, L. E. Mississippi River test: Volume 1: Final report,DCP4400/300, prepared for the U.S. geological sur- vey by AMETEK/Straza division [R]. E1 Cajon, California, under contract No. 14-08-0001-19003,1982.
  • 8Oberg,K.A., Morlock,S.E., Caldwell,W.S. Quality-assurance plan for discharge measurements using acoustic Doppler current profilers[R]. U.S. Geological Survey Scientific Investigations Report,2005.
  • 9MueIler,D.S., Wagner, C.R. Measuring discharge with acoustic Doppler current profilers from a moving boat [R].U.S. Geological Survey Techniques and Methods, 2009.
  • 10United States Geological Survey. Exposure time for ADCP moving- boat discharge measurements made during steady flow conditions [R]. Office of Surface Water Technical Memorandum, September 11, 2011.