为了实现复杂电网环境下对基波和任意次谐波精细化检测补偿的需求,基于传统i_(p)-i_(q)检测法设计了一种对基波和任意次谐波电流的多功能精细检测新方法。基于瞬时无功功率理论给出了谐波电流有功/无功分量的定义,通过使用单锁相环结合倍频器的方法获取了各指定次谐波的频率信号,利用相位合成补偿的方法改进了传统ip-iq法的Park变换矩阵,设计了直流分量积分提取法代替传统方法中的低通滤波器。该方法弥补了传统检测方法的功能性不足,并具有更高的检测速度和检测精度。通过MATLAB/Simulink仿真分析,验证了所提方法的有效性和灵活性。
To realize the requirement of refined detection and compensation of fundamental and arbitrary harmonics in complex power grid environment,a new multi-functional refined detection method for fundamental and arbitrary harmonics is designed based on the traditional ip-iq detection method.Based on the instantaneous reactive power theory,the definition of the active/reactive component of harmonic current is given.The frequency signals of the specified harmonics are obtained by using a single phase-locked loop combined with frequency multiplier.The Park transform matrix of the traditional ip-iq method is improved by using the phase synthesis compensation method,and the DC component integral extraction method is designed to replace the low-pass filter in the traditional method.This method makes up for the lack of functionality of traditional detection methods,and has higher detection speed and accuracy.The effectiveness and flexibility of the proposed method are verified by MATLAB/Simulink simulation.
作者
王一帆
裘智峰
张亮
Wang Yifan;Qiu Zhifeng;Zhang Liang(School of Automation,Central South University,Changsha 410083,China)
出处
《电子测量技术》
北大核心
2021年第11期1-8,共8页
Electronic Measurement Technology
基金
国家自然科学基金项目(62073335,61988101,U1701261)
国家自然科学基金面上项目(62073345)资助。
关键词
瞬时无功功率理论
相位补偿
指定次谐波检测
谐波电流有功/无功分量
instantaneous reactive power theory
phase compensation
specified frequency harmonic detection
active/reactive component of harmonic current