摘要 随着我国社会发展进步,电缆线路的铺设速度愈发加快。交联聚乙烯电缆凭借其优良的运行性能,在国内广泛铺设,但囿于复杂的运行环境,电缆常因此受到不同程度的绝缘老化。目前,在高压交联电缆线路现场试验和状态检测中,阻尼振荡波电压下的局部放电实验还未有重大突破,缺乏相关的实验数据。文中介绍了振荡波局部放电实验的原理及其实验装置,并对通过对比分析三条绝缘老化程度差异明显、在电缆接头与终端分别出现绝缘缺陷的电力电缆,得到了绝缘老化程度与电缆局部放电参数(放电起始电压、放电电量等)之间的相对关系。凭借局部放电定位的手段,进行了电缆绝缘老化故障的位置分析,并证明了阻尼振荡波电压下的局部放电实验的优良性与适用性。 With the progress of the social development of our country,the laying speed of the cable line is increasing.The cross-linked polyethylene cable is widely laid in the country by virtue of its excellent operating performance,but in a complex operating environment,the cable is often subjected to different degree of insulation aging.At present,in the field test and state detection of the high-voltage cross-link cable,there is no significant breakthrough in the partial discharge experiment under the voltage of the ringing wave,and the relevant experimental data is not available.In this paper,the principle of partial discharge experiment of oscillation wave and its experimental device are introduced.The relative relationship between the insulation aging degree and the partial discharge parameters(discharge initial voltage,discharge electricity,etc.)of the cable is obtained by comparing and analyzing three power cables withobvious difference ininsulation aging degree and insulation defects in the cable joint and terminal.By means of partial discharge location,the location analysis of cable insulation aging fault is carried out,and the advantages and applicability of partial discharge experiment under damping oscillatory wave voltage are proved.
作者 李巍巍 白欢 吴惟庆 杨兰 朱轲 张睿 赵莉华 Li Weiwei;Bai Huan;Wu Weiqing;Yang Lan;Zhu Ke;Zhang Rui;Zhao Lihua(State Grid Sichuan Electric Power Research Institute,Chengdu 610065,China;School of Electrical Engineering,Sichuan University,Chengdu 610065,China)
出处 《电测与仪表》 北大核心 2021年第9期147-151,共5页 Electrical Measurement & Instrumentation
基金 国网四川省电力公司科技项目"交联聚乙烯电力电缆火灾早期特征研究"(52199718001Q)。
关键词 振荡波 交联聚乙烯 电力电缆 在线监测 局部放电 oscillating-wave cross-linked polyethylene power cable online monitoring partial discharge
  • 相关文献

参考文献21

二级参考文献215

共引文献526

同被引文献482

引证文献38

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部