摘要
结合气相色谱仪实验室使用经验,归纳总结气相色谱仪在使用过程中气路系统和进样系统常见的故障及其解决办法。气路系统故障主要为气密性问题,需使用专业的检测仪器进行故障排查;进样系统故障主要为填充柱故障及毛细柱故障,解决方法主要为排除法对其故障进行分析并解决。同时梳理实验室气相色谱仪使用技术维护要点,为保障其运行稳定性、分离有效性及检测精度提供建议。
Based on the experience of using gas chromatograph in laboratory,this paper summarizes the application of gas chromatograph Common faults of gas path system and injection system and their solutions.The main fault of gas system is air tightness,so professional testing instruments are needed for troubleshooting;The main faults of the injection system are packed column faults and capillary column faults,and the main solution is to analyze and solve the faults by troubleshooting.At the same time,the key points of technical maintenance of laboratory gas chromatograph were summarized to ensure its operation stability,separation effectiveness and detection accuracy.
出处
《化工设计通讯》
CAS
2021年第8期64-65,共2页
Chemical Engineering Design Communications
关键词
气相色谱仪
故障分析
技术维护
gas chromatograph
fault analysis
technical maintenance