结合LNG接收站的工程设计,对LNG接收站储罐区的泄漏点进行辨识及分析,并结合国内标准规范及NFPA59A—2019对LNG的泄漏量、集液池容积、蒸汽云扩散隔离区范围及火灾热辐射影响范围进行分析,为接收站的选址及总平面布置提供设计依据。
Combined with the engineering design of the LNG receiving station,the leakage point of the LNG receiving station storage tank area is identified and analyzed,and combined with the domestic standard specifications and NFPA59A-2019,the LNG leakage volume,sump volume,vapor cloud diffusion isolation area Analyze the scope and the influence scope of fire heat radiation to provide a design basis for the site selection and general layout of the receiving station.
出处
《化工设计通讯》
CAS
2021年第8期102-103,共2页
Chemical Engineering Design Communications
关键词
LNG接收站
集液池
泄漏
扩散
热辐射
LNG receiving station
sump
leakage
diffusion
heat radiation