摘要
文中以某电厂汽轮机热力性能试验为例,对在试验期间由于阀门内漏,致使计算求得的热耗率数据出现异常进行了分析,说明了系统隔离的重要性。
Taking a thermal performance test of a steam turbine in a power plant as an example,this paper analyzes the abnormality of the calculated heat rate data due to valve internal leakage during the test,and illustrates the importance of system isolation.
作者
吴哲
WU Zhe(National Energy Group Shandong Shiheng Thermal Power Co.,Ltd.,Feicheng 271621,China)
出处
《应用能源技术》
2021年第8期22-26,共5页
Applied Energy Technology
关键词
汽轮机
性能试验
系统隔离
steam turbine
performance test
system isolation