摘要
分析了我国工业厂房关于爆炸性粉尘环境分区的标准及不同行业标准对相应分区的要求,通过对比美国消防协会(NFPA)、德国工程师协会(VDI)等国际标准化组织关于爆炸性粉尘防爆标准体系的构成及特点。针对工程建设中工业厂房关于爆炸性粉尘环境分区要求存在的问题,提出了我国粉尘防爆标准化的建议。
Analyzes the standards of explosive dust atmosphere zoning in industrial buildings and the requirements of different industry standards for the corresponding zoning,and compares the composition and characteristics of explosive dust explosion-proof standard system of international standardization organizations such as NFPA and VDI.In view of the problems existing in the requirements of explosive dust atmosphere zoning for industrial buildings in engineering construction,this paper puts forward some suggestions on dust explosion-proof standardization.
作者
袁亮
李飞
李昌剑
严福红
周开翔
YUAN Liang;LI Fei;LI Changjian;YAN Fuhong;ZHOU Kaixiang(China Light Industry Wuhan Design Engineering Co.,Ltd.,Wuhan 430060,China;Shanghai Morimatsu Pharmaceutical Equipment Engineering Co.,Ltd.,Shanghai 201323,China)
出处
《现代食品》
2021年第16期90-95,98,共7页
Modern Food
关键词
爆炸性粉尘环境
分区
防爆
explosive dust atmosphere
zoning
explosion-proof