直埋无补偿冷安装供热管道应变现场试验研究 被引量:3

Field test study on stress of directly buried non-compensated cold installed heating pipeline
下载PDF
导出
摘要 针对直埋无补偿供热管道轴向应变展开现场试验研究。采用高温应变片和无线传输应变仪对直管段供水管和回水管进行了一个供暖周期的数据测量。试验结果显示,供热管道工作时应变状态较为复杂,同一截面上的轴向应变不均匀,受温度和外部因素影响较大。管道存在随机的弯曲变形,在设计和施工时,应充分考虑以上因素,做好防护,以保证管道安全运行。 The field test of axial strain of directly buried uncompensated heat supply pipeline is carried out.High temperature strain gauges and wireless transmission strain gauge are used to measure the straight section axial strain of water supply pipe and return pipe in a heating cycle.The test results show that the heating pipeline strain is complex in working state,the axial strain is uneven on the same section,and it is greatly affected by the temperature and external factors.The pipeline has random bending deformation,therefore,in design and construction,the above factors should be fully considered,and the protection should be done to ensure the safe operation of the pipeline.
作者 李晓芝 刘明泉 Li Xiaozhi;Liu Mingquan(School of Civil Engineering,Tangshan University,Tangshan 063000,China;Hebei Key Laboratory of Building Engineering and Tailings Utilization,Tangshan 063000,China)
出处 《山西建筑》 2021年第19期104-105,共2页 Shanxi Architecture
基金 河北省建设科技计划项目(2020-05-08)。
关键词 供热管道 直埋 无补偿 轴向应变 现场试验 heating pipeline directly buried non-compensated axial strain field test