期刊文献+

Design and experiment of low-frequency ultrasonic nozzle integrating air-assistant system and acoustic levitation mechanism 被引量:1

原文传递
导出
摘要 Ultrasonic atomization nozzles are generally divided into two categories:high frequency and low-frequency ultrasonic atomization nozzles.Compared with high-frequency ultrasonic atomization nozzles(working frequencies>1 MHz),low-frequency ultrasonic atomization nozzles are not sensitive to clarity,temperature and viscosity of the liquid.However,they can control atomization quantity precisely,but the sizes of droplets generated by them are relatively large.In aeroponics cultivation,and precision welding,in such both cases,precise spraying control and tiny droplet sizes are expected.Therefore,how to decrease droplet size using low-frequency ultrasonic atomization nozzles is a valuable issue.In this paper a 60 kHz low-frequency ultrasonic atomization nozzle integrating air-assistant system and acoustic levitation mechanism was proposed and designed.Furthermore,the design was verified by FEA(Finite Element Analyzes)and impedance analyzer PV70A,and the verified results indicated relative design error was 0.49%.Driving voltage,spout angle,air pressure and levitating ball were taken as influential factors in the experimental protocol to the character in spray properties of this designed nozzle.A laser particle size analyzer was used to measure droplet sizes.Experiment results indicated that:the diameters of droplets generated by this nozzle at driving voltage 46 V were smaller than those at 40 V driving voltage;Both the assistant air and levitation mechanism could effectively change the diameters and uniformity of droplets;The minimum values of D10,D50,and D90(D10,D50 and D90 were mean diameters when cumulative percentages of the samples’diameter were 10%,50%and 90%,respectively)were 23.06μm,31.14μm and 41.38μm,respectively.However,all those minimum values were presented at the same run(spout angle 0°,air pressure 0.05 MPa,having levitated ball,driving voltage 46 V);Levitating ball above the atomization surface would make droplet sizes more uniform and tinier.More importantly,the famous Lang equation which assumes that droplet diameters just decided by the liquid surface tension,density and ultrasonic atomizer’s working frequency needed to be revised because experimental results indicated that changing vibration amplitudes of ultrasonic atomization surface might lead to the changing of the droplet diameters and those results were at odds with the Lang equation.
出处 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2020年第6期25-33,共9页 国际农业与生物工程学报(英文)
基金 We acknowledge that this work was financially supported by the National Natural Science Foundation of China Program(No.51975255) Jiangsu Agriculture Science and Technology Innovation Fund(CX(18)3048) and the“Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(No.37,(2014)).
  • 相关文献

参考文献1

二级参考文献1

共引文献2

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部