摘要
通过深圳月亮湾综合车场地面电动公交车库复合通风设置,以及地下一层混合车库通风量和排烟量计算、风机选型、通风和排烟系统设置,针对高层电动公交车库防火单元划分,电动汽车库排风和排烟排出气体类型、排风系统控制方式等问题,进行探讨,并提出建议。
Through compound ventilation settings of Shenzhen Moon Bay electric bus garage,and ventilation and smoke exhaust volume calculation,fan selection,ventilation and smoke exhaust system settings of underground garage,the electric car exhaust and smoke exhaust gas type,exhaust system control method for electric bus garage fire unit division were discussed,and suggestions were put forward.
作者
刘慕云
LIU Mu-yun(Shanghai Urban Traffic Design Institute Co.,Ltd)
出处
《建筑热能通风空调》
2021年第7期100-103,共4页
Building Energy & Environment
关键词
高层电动公交车库
电动汽车库
充电设施
通风和排烟
防火单元
high-rise electric bus garage
electric garage
charging facility setting
ventilation and smoke extraction
fire unit