摘要
介绍天然气门站调压前天然气升温方案:方案1:防爆电加热器。方案2:燃气锅炉+换热器。方案3:空气源热泵型加热器。以某天然气门站作为研究对象,计算分析3种方案的经济性、环保性,方案3的年运行费用、年二氧化碳排放量均最低。
The heating schemes of natural gas before pressure regulation of natural gas gate station are introduced.Scheme 1:explosion-proof electric heater.Scheme 2:gas-fired boiler+heat exchanger.Scheme 3:air-source heat pump heater.Taking a natural gas gate station as the research object,the economy and environmental protection of the three schemes are calculated and analyzed.The annual operation cost and annual carbon dioxide emissions of scheme 3 are the lowest.
作者
张新华
范迪
刘誉阳
郑威
ZHANG Xinhua;FA Di;LIU Yuyang;ZHENG Wei
出处
《煤气与热力》
2021年第9期V0008-V0010,V0044,V0045,共5页
Gas & Heat
关键词
空气源热泵
门站
天然气加热器
air-source heat pump
gate station
natural gas heater