摘要
通过对合肥市15个地温监测孔的长期观测,分析了该市浅层地温场的分布特征及其影响因素。研究结果表明:合肥市浅层地温场整体呈西低东高分布特征,区内恒温带平均温度在17.4℃左右,恒温带深度在12~32m左右,地温梯度在2.3~4.1℃之间。浅层地温场主要受地质构造控制,同时受地层岩性及地下水补径排条件影响。200m以浅岩性以泥岩、砂岩为主,胶结程度差,结构松散,且地下水贫乏,浅层地温能的开发利用适宜采用地埋管型地源热泵。
Based on a year-long survey of 15 geothermal observation holes in Hefei,a temperature monitoring curve and ground temperature distribution map were drawn.The distribution characteristics of the shallow geothermal field are westlow and east-high;the average temperature in the constant temperature zone is approximately 17.4℃;the depth of the constant temperature zone is approximately 12-32 m;and the geothermal gradient is between 2.3℃ and 4.1℃.Based on these findings,we believe that the shallow geothermal field is mainly controlled by the geological structure;but it is also affected by formation lithology,groundwater recharge,and discharge conditions.Specifically,the lithology from a depth of 200 m to the shallow lithology is composed of a sandstone-based mudstone with poor cementation and a loose structure,and the groundwater is poor.This indicates that the development and utilization of shallow geothermal energy is suitable for ground-source heat pumps with buried pipes.
作者
李静
张帅
刘亚兰
何黎明
LI Jing;ZHANG Shuai;LIU Yalan;HE Liming(The First Institute of Hydrogeology and Engineering Geological Prespecting of Anhui Prespecting,Anhui Bengbu 233000,China)
出处
《上海国土资源》
2021年第3期33-37,共5页
Shanghai Land & Resources
基金
中国地质科学院地质调查工作项目“合肥市浅层地温能调查评价”(1212011120060
1212011120837)。
关键词
浅层地温能
地温场
分布特征
影响因素
shallow geothermal energy
geothermal field
distribution characteristics
influencing factors