人工耳蜗植入儿童1000 Hz探测音ESR测试刺激持续时间的研究

Study on Optimal Setting of Stimulus Duration in ESR Measurement with 1000 Hz Probe Tone for Cochlear Implant Users
下载PDF
导出
摘要 目的探讨人工耳蜗植入术后1000 Hz探测音电诱发镫骨肌反射(electrically evoked stapedius reflex,ESR)测试中刺激持续时间的最佳设置,及其阈值(electrically evoked stapedius reflex threshold,ESRT)与最大舒适阈值(most comfortable level,MCL值)之间的关系。方法选取植入MED-EL SonataTi100型人工耳蜗的患儿21例(年龄2~11岁,平均7.80±2.21岁,人工耳蜗至少使用一年且效果良好)。对17例受试者进行刺激持续时间分别为300、500、800和1000 ms的1000 Hz探测音ESR测试,对其余4例受试者进行500 ms刺激持续时间的ESR测试,测试电极为2、6、11号电极,获取相应的ESRT,并记录相应电极的MCL值。对三个电极四种刺激持续时间的ESRT进行重复测量方差分析,对500 ms刺激持续时间的ESRT和MCL值进行相关性和线性回归分析。结果21例受试者500 ms刺激持续时间的ESR总引出率为90.48%(57/63)。17例受试者每个电极300 ms刺激持续时间的ESRT均显著高于500、800和1000 ms刺激持续时间的ESRT(P<0.05);而每个电极500、800及1000 ms刺激持续时间的ESRT之间均无显著差异(P>0.05);每种刺激持续时间的三个电极之间的ESRT差异有统计学意义(P<0.05),11号电极的ESRT最大,6号次之,2号最小。500 ms刺激持续时间的三个电极的ESRT与MCL值均显著相关(P<0.01)。结论人工耳蜗植入儿童1000 Hz探测音ESR测试中推荐使用≥500 ms的刺激持续时间,其阈值可指导MCL值的调试。 Objective To study the optimal setting of stimulus duration in electrically evoked stapedius reflex(ESR)measurement with high-frequency(1000 Hz)probe tone after cochlear implantation,and the relationship between electrically evoked stapedius reflex threshold(ESRT)and most comfortable level(MCL).Methods Twenty-one pediatric patients(implanted with a MED-EL SonataTi100 cochlear)participated in this study.They had been using the cochlear for at least a year with good results and considerable ability of communication,and could cooperate with subjective and objective tests.ESR measurements with high-frequency(1000 Hz)probe tone were performed on 17 participants,whose stimulus durations were setted at 300,500,800 and 1000 ms,respectively.The remaining 4 participants were tested for the stimulus duration of 500 ms.Three cochlear electrods of 2,6,11 were selected for the ESR measurement.The corresponding ESRT was Obtained after tests and the MCL of the corresponding electrod was recorded in the common program.Then repeated measurement analysis of ANOVA was performed for ESRTs of three tested electrods with four stimulus durations,and correlation and linear regression analysis were performed for ESRTs with 500 ms stimulus duration and MCLs.Results The total elicitation rate of ESR measurement was 90.48%(57/63)in 21 participants with 500 ms stimulus duration.The ESRTs of each tested electrode under the condition of 300 ms stimulus duration were significantly higher than those of under the conditions of 500 ms,800 ms and 1000 ms stimulus durations(P<0.05).There were no significant differences among ESRTs of each tested electrode under the conditions of 500,800 and 1000 ms stimulus durations(P>0.05).There were significant differences among ESRTs with electrodes of 2,6,11 under the condition of each stimulus duration(P<0.05).The ESRTs of electrode 11 were the largest and those of electrode 2 were the smallest.There were significant correlations between ESRTs with 500 ms stimulus duration and MCLs of three electrodes(P<0.01).Conclusion Stimulus durations≥500 ms are recommended for ESR measurement with high-frequency(1000 Hz)probe tone.ESRT with high-frequency(1000 Hz)probe tone could guide the setting of MCL after cochlear implantation.
作者 郭浩伟 危艳萍 林碧玉 李燕萍 陈婷 Guo Haowei;Wei Yanping;Lin Biyu;Li Yanping;Chen Ting(Department of Otolaryngology,Shengli Clinical Medical College of Fujian Medical University,Fujian Provincial Hospital,Fuzhou,350001,China;不详)
出处 《听力学及言语疾病杂志》 CAS CSCD 北大核心 2021年第5期522-525,共4页 Journal of Audiology and Speech Pathology
基金 福建医科大学启航基金项目(2018QH1163)。
关键词 电诱发镫骨肌反射 刺激持续时间 最大舒适阈值 人工耳蜗植入 Electrically evoked stapedius reflex Stimulus duration Most comfortable level Cochlear implant
  • 相关文献

参考文献2

二级参考文献14

  • 1莫玲燕,陈雪清,刘莎,刘博,王硕,孔颖,赵啸天,郑军,李永新,韩德民.人工耳蜗术后电诱发镫骨肌反射[J].听力学及言语疾病杂志,2004,12(5):289-290. 被引量:3
  • 2[2]Jerger J,Jenkins H,Fifer R,et al.Stapedius reflex to electrical stimulation in a patient with a cochlear implant.Ann Otol Rhinol Laryngol,1986,95(2 Ptl):151-157.
  • 3[3]Spivak LG,Chute PM.The relationship between electrical acoustic reflex thresholds and behavioral comfort levels in children and adult cochlear implant patient.Ear Hear,1994,15(2):184-192.
  • 4[4]Hodges AV,Balkeny TJ,Ruth RA,et al Electrical middle ear muscle reflex:use in cochlear implant programming.Otolaryngol Head Neck Surg,1997,117(3Pt 1):255-261.
  • 5[5]Battmer RD,Laszig R,Lehnhardt E.Electrically elicited stapedius reflex in cochlear implant patients.Ear Hear,1990,11 (5):370-374.
  • 6[6]Todd NW,Ajayi E,Hasenstab MS,et al.Childhood otitis media and electrically elicited stapedius reflexes in adult cochlear implantees.Otol Neurotol,2003,24(4):621-624.
  • 7[7]Nadol JB Jr.Patterns of neural degeneration in the human cochlea and auditory nerve:implications for cochlear implantation.Otolaryngol Head Neck Surg,1997,117(3 Pt1):220-228.
  • 8[8]Jerger J,Oliver TA,Chmiel,RA.Prediction of dynamic range from stapedius reflex in cochlear implant patients.Ear Hear,1988,9(1):4-8.
  • 9[9]Frijns JH,Briaire JJ,de Laat JA,et al.Initial evaluation of the clarion CR cochlear implant:speech perception and neural response imaging.Ear Hear,2002,23(3):184-197.
  • 10[10]Gordon KA,Papsin BC,Harrison RV.Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children.Ear Hear,2004,25(5):447-463.

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部