摘要
验证了Anoop Adhyapak等人提出的参考场地法参考值的获取方法,发现该方法在3 m和5 m的测量距离下是有效的,但推广到10 m的测量距离时存在一些局限性。同时利用在中国计量科学研究院标准开阔场获取的不含地面反射的一组参考数据所构造的反卷积滤波器,在常规的EMC暗室中验证并复现了在3 m测量距离参考值的有效性,这将为暗室的期间核查提供一种新的方法。
The method for obtaining the reference value of reference site method proposed by Anoop Adhyapak et al.is verified,and it is found that the method is effective at the measurement distance of 3 m and 5 m,but there are some limitations when the method is extended to the measurement distance of 10 m.At the same time,a deconvolution filter is constructed based on a set of reference data obtained from the standard open field of National Institute of Metrology without ground reflection,and the validity of the reference value measured at 3 m is verified and reproduced in a conventional EMC anechoic chamber.This will provide a new method for the period check of anechoic chamber.
作者
吴壮
王维龙
崔强
刘科
Wu Zhuang;Wang Weilong;Cui Qiang
出处
《安全与电磁兼容》
2021年第5期33-36,55,共5页
Safety & EMC
基金
国家重点研发计划(2017YFF0206201)。
关键词
反卷积滤波器
时间窗
参考场地法
自由空间天线系数
EMC暗室
deconvolution filter
time window
reference site method
free space antenna coefficient
EMC anechoic chamber