期刊文献+

青海新能源电站高电压穿越试验平台应用设计 被引量:1

Application Design of Qinghai New Energy Power Station High Voltage Ride Through Test Platform
下载PDF
导出
摘要 对建设新能源电站高电压穿越试验平台进行原理分析,提出适用于青海高海拔地区新能源及储能电站高电压穿越平台的设计应用方法,在此基础上对青海电力公司高电压穿越试验平台建成投运进行系统描述,可为新能源储能联合发电系统高电压穿越检测提供参考。 The principle analysis of the high voltage ride through test platform for the construction of new energy power stations is carried out,and a design and application method suitable for the high voltage ride through platform of new energy and energy storage power stations in Qinghai high altitude areas is proposed.On this basis,the high voltage ride through test of Qinghai Electric Power Company The platform is completed and put into operation for system description,which can provide a reference for the high voltage ride through detection of the new energy storage combined power generation system.
作者 李东升 杨军 闫涵 杨凯璇 LI Dongsheng;YANG Jun;YAN Han;YANG Kaixuan
出处 《青海电力》 2021年第3期39-43,共5页 Qinghai Electric Power
关键词 新能源电站 高电压穿越 试验平台 应用设计 new energy power station high voltage ride through test platform application design
  • 相关文献

参考文献5

二级参考文献49

  • 1王琦,陈小虎,纪延超,李枫.基于双同步坐标的无刷双馈风力发电系统的最大风能追踪控制[J].电网技术,2007,31(3):82-87. 被引量:33
  • 2王同勋,薛禹胜,S.S.CHOI.动态电压恢复器研究综述[J].电力系统自动化,2007,31(9):101-107. 被引量:94
  • 3ERLICH I,BACHMANN U. Grid code requirements concerning and operation of wind turbines in Germany[A].New York,USA,2005.1253-1257.
  • 4CASE C. Connecting wind farms to the grid-what you need to know[R].2006.
  • 5DATTA R,RANGANATHAN V T. Variable-speed wind power generation using doubly fed wound rotor induction machine-a comparison with alternative schemes[J].IEEE Transactions on Energy Conversion,2002,(03):414-442.doi:10.1109/TEC.2002.801993.
  • 6XIANG Dawei,LI Ran. Control of a doubly fed induction generator in a wind turbine during grid fault ride-through[J].IEEE Transactions on Energy Conversion,2006,(03):652-662.
  • 7RATHI M R,MOHAN N. A novel robust low voltage and fault ride through for wind turbine application operating in weak grids[A].Raleigh,NC,USA,2005.1-6.
  • 8MORREN J,de HAAN S W H. Ride-through of wind turbines with doubly-fed induction generator during a voltage dip[J].IEEE Transactions on Energy Conversion,2005,(02):435-441.doi:10.1109/TEC.2005.845526.
  • 9NIIRANEN J. Voltage dip ride through of doubly-fed generator equipped with active crowbar[A].Gothenburg,Sweden,2004.56-59.
  • 10WESSELS C,GEBHARDT F,FUCHS F W. Fault ridethrough of a DFIG wind turbine using a dynamic voltage restorer during symmetrical and asymmetrical grid faults[J].IEEE Transactions on Power Electronics,2011,(02):807-815.

共引文献52

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部