期刊文献+

风力发电机绕组分布参数对过电压分布影响研究 被引量:1

Influence of Winding Distribution Parameters on Over-voltage Distribution of Wind Generator
下载PDF
导出
摘要 分析永磁风力发电机绕组分布参数对电机内部过电压分布的影响,对绕组绝缘设计具有重要意义。针对永磁风力发电机定子绕组的结构特点,利用有限元分析软件建立定子槽模型并计算其分布参数。对来自变流器的陡上升沿高频脉冲电压作用下的定子绕组过电压分布特性进行仿真分析,研究绕组分布参数对匝间过电压分布的影响,并讨论改变分布参数对优化过电压分布的效果。通过对绕组分布参数的研究,提出改善绕组过电压不均匀分布的初步措施。 Analyzing the influence of permanent magnet wind generator winding distribution parameters on the internal over-voltage of the motor winding to design winding insulation importantly.According to the structure characteristics of stator windings of permanent magnet wind generator,finite element analysis software was used to establish a stator slot model and calculate distribution parameters.The voltage distribution characteristics of stator winding under pulse voltage with steep rise were simulated,the influence of distribution parameters on voltage distribution was studied,and the effect of over-voltage distribution optimization by changing distribution parameters was analyzed.Based on the study of winding voltage distribution characteristics,proposed the preliminary measures to improve the uneven distribution of winding overvoltage.
作者 秦钰 何山 董宁 郑海旺 QIN Yu;HE Shan;DONG Ning;ZHENG Haiwang(School of Electrical Engineering, Xinjiang University, Urumqi 830049, China;Engineering Research Center of Ministry of Education for Renewable Energy Power Generation and Grid Connection Technology, Urumqi 830049,China)
出处 《微电机》 2021年第9期13-17,共5页 Micromotors
基金 国家自然科学基金项目,永磁风力发电机绕组过电压致损规律及保护对策研究(51767024)。
关键词 定子绕组 有限元分析(FEA) 分布参数 过电压分布 stator winding FEA distributed parameters over-voltage distribution
  • 相关文献

参考文献4

二级参考文献36

  • 1咸哲龙,姜建国,曹海翔.电机定子结构及其绝缘介电常数的频率特性对定子绕组电容值的影响[J].中国电机工程学报,2004,24(8):129-133. 被引量:8
  • 2邹祖冰,蔡丽娟,甘辉霞.基于非线性解耦控制的三相电压型SPWM逆变器[J].中国电机工程学报,2004,24(10):57-60. 被引量:16
  • 3张兴,张显立,谢震,吴玉杨.双馈风力发电变流器长缆驱动及其过电压抑制[J].电力系统自动化,2006,30(21):44-48. 被引量:18
  • 4GB/T 21707-2008,变频调速专用三相异步电动机绝缘规范[S].
  • 5Von Jouanne A, et al. Application issues for PWM adjustable speed AC motor drives. IEEE Industry Application Magazine, 1996: 10~18.
  • 6Kaufhold M. Electrical stress and failure mechanism of the winding insulation in PWM-Inverter-Fed low- vol-tage induction motors. IEEE Transactions on Industrial Electronics, 2000, 47(2): 396~402.
  • 7Suresh G, Hamid A Toliyat, et al. Predicting the transient effects of pwm voltage waveform on the stator windings of random wound induction motors. IEEE Transactions on Power Electronics,1999,14: 23~30.
  • 8Yifan Tang. Analysis of steep-fronted voltage and turn insulation failure in inverter fed AC motor. Industry Applications Conference, 1997, 1: 509~516.
  • 9Gubbala L, von Jouanne A, Enjeti P, et al. Voltage distribution in the windings of an ac motor subjected to high dv/dt PWM voltages. Power Electronics Specialists Conference, 1995,1: 579~585.
  • 10Skibinski G, Kerkman R, Leggate D, et al. Reflected wave modeling techniques for PWM AC motor drives. Applied Power Electronics Conference and Exposition, 1998, 2: 1021~1029.