针对当前复合材料上层建筑与钢质主船体之间螺栓机械连接形式Π形接头和L形接头的强度较弱、易发生损坏的问题,从增强复合材料接头强度角度,提出一种加强L形接头,进行相应的拉伸试验和数值仿真计算,并将其与现有的Π形接头、L形接头进行对比,结果表明,加强L形接头的强度更好。
Aiming at the problems of weak strength and easy damage of∏-joints and L-joints in bolt mechanical connection between composite superstructure and steel main hull,a kind of reinforced L-joint was proposed to enhance the strength of composite joint.The corresponding tensile tests and numerical simulation were carried out.Comparation of the numerical results with that of the existing∏-joints and L-joints showed that the strength of reinforced L-joint is better.
作者
徐双喜
佟哲
董威
唐卫国
张浩
XU Shuang-xi;TONG Zhe;DONG Wei;WU Yi-gang;ZHANG Hao(a.School of Transportation,Wuhan University of technology,Wuhan 430063,China;Key Laboratory of High Performance Ship Technology,Ministry of Education,Wuhan University of technology,Wuhan 430063,China;Research Institute of Advanced Material Manufacturing Equipment and Technology,Wuhan University of technology,Wuhan 430063,China;Key Laboratory of ship vibration and noise,China Ship Research and design center,Wuhan 430064;Qingdao Branch of Institute of Software,Chinese Academy of Sciences,Qingdao Shandong,266000,China)
出处
《船海工程》
北大核心
2021年第5期42-46,共5页
Ship & Ocean Engineering
关键词
复合材料
上层建筑
螺栓连接
连接接头
接头强度
composite material
superstructure
bolt connection
connection joint
joint strength