期刊文献+

外骨骼柔顺膝关节作动机构研究

Study on Compliant Actuator of the Knee Joint for Exoskeleton
下载PDF
导出
摘要 外骨骼关节的柔顺性在适应穿戴者不同运动状态和人机相容性方面至关重要,然而,常见的刚性机构和被动柔顺机构不能够实时反馈人机交互力从而达到主动柔顺的目的。设计了一种主动柔顺膝关节作动机构,利用拮抗驱动原理结合曲柄滑块的力位转换能力,使其不仅能够达到利用传统串联弹性驱动增加机构柔顺的目的,还可以通过该柔顺机构实时计算人机交互力。实验证明了该柔顺机构的可行性和有效性。 The compliance of the joint for exoskeleton is very important in adapting to the wearer’s motions and human-machine compatibility.However,the conventional rigid or passive compliant mechanisms cannot achieve the purpose of active compliance due to the non-real-time feedback of the human-machine interaction forces.Therefore,an active compliant actuator of the knee joint is developed,using of the antagonistic driving principles and the force-position transformation of the slider-crank mechanism,which can not only implement the compliance of the traditional series elastic actuator,but also can obtain the real-time human-machine interaction forces.Finally,the feasibility and effectiveness of the compliant actuator are verified by tests.
作者 纪平鑫 宋鹏 莫新民 韦祖拔 赵浩 Ji Pingxin;Song Peng;Mo Xinmin;Wei Zuba;Zhao Hao(Northwest Institute of Mechanical&Electrical Engineering,Xianyang 712099,China;Xi'an Exo-Smart Dynamics Technology Co.,Ltd.,Xi'an 712000,China;School of Mechatronical Engineering,Beijing Institute of Technology,Beijing 100081,China)
出处 《机械传动》 北大核心 2021年第10期96-99,共4页 Journal of Mechanical Transmission
关键词 膝关节外骨骼 柔顺作动机构 力矩估计 Knee joint for exoskeleton Compliant actuator Torque estimation
  • 相关文献

参考文献3

二级参考文献108

  • 1归丽华,杨智勇,顾文锦,张远山,杨秀霞.能量辅助骨骼服NAEIES的开发[J].海军航空工程学院学报,2007,22(4):467-470. 被引量:27
  • 2雷兵.协行助力机械腿结构优化及性能评估系统研究[D].上海:华东理工大学,2011.
  • 3Bogue R. Exoskeletons and robotic prosthetics: A review of re-cent developments[J]. Industrial Robot, 2009, 36(5): 421-427.
  • 4Dollar A M, Herr H. Lower extremity exoskeletons and activeorthoses: Challenges and state-of-the-art[J]. IEEE Transactionson Robotics, 2008, 24(1): 144-157.
  • 5Jimenez-Fabian R,Verlinden O. Review of control algorithmsfor robotic ankle systems in lower-limb orthoses, prostheses,and exoskeletons [J]. Medical Engineering & Physics, 2012,34(4): 397-408.
  • 6Kazerooni H, Steger R, Huang L H. Hybrid control of theBerkeley lower extremity exoskeleton (BLEES)[J]. Internation-al Journal of Robotics Research, 2006, 25(5/6): 561-573.
  • 7Walsh C J, Paluska D,Pasch K, et al. Development of alightweight, underactuated exoskeleton for load-carrying aug-mentation[C]//IEEE International Conference on Robotics andAutomation. Piscataway, USA: IEEE, 2006: 3485-3491.
  • 8Kawamoto H, Lee S, Kanbe S, et al. Power assist method forHAL-3 using EMG-based feedback controller[C]//IEEE Inter-national Conference on Systems, Man and Cybernetics. Piscat-away, USA: IEEE, 2003: 1648-1653.
  • 9Huang Y,Wang Q N, Chen B J, et.al. Modeling and gait selec-tion of passivity-based seven-link bipeds with dynamic series ofwalking phases [J]. Robotica, 2012,30(1): 39-51.
  • 10Seyfarth A, Iida F, Tausch R,et al. Towards bipedal jogging asa natural result of optimizing walking speed for passively com-pliant three-segmented legs[J]. International Journal of RoboticsResearch, 2009, 28(2): 257-265.