期刊文献+

黄河公轨合建隧道火灾人员疏散安全研究 被引量:4

Research on the evacuation safety of Yellow River road-rail tunnel
下载PDF
导出
摘要 以济南黄河公轨合建隧道为研究对象,分别对公路隧道和轨道交通发生火灾时,纵向疏散楼梯和横向疏散门的间距对人员疏散时间的影响进行分析,获得必需疏散时间。结果表明:疏散楼梯间距为60m和75m时,均满足安全疏散要求;轨道交通发生火灾,在通风有效情况下,人员可用安全疏散时间TASET为2700s;疏散门间距为150m和300m时,均满足安全疏散要求。从安全和运行成本考虑,推荐疏散楼梯间距设置为75m、下层疏散门间距设置为300m。 Taking the Jinan Yellow River road-rail tunnel as the research object,the impact of the distance between the vertical evacuation stairs and the horizontal evacuation door on the evacuation time of the people in the case of road tunnels and rail transit fires was analyzed,and the necessary evacuation time was obtained.The results show that when the distance between any two evacuation stairs is 60 m and 75 m,it meets the requirements for safe evacuation.When a fire occurs in rail transit,the available safe evacuation time is 2700 s under effective ventilation.When the distance between any two evacuation doors is 150 m and 300 m,it meets safety evacuation requirements.Considering safety and operating costs,it is recommended to set the distance between the evacuation stairs as 75 m and the distance between the evacuation doors of the lower storey as 300 m.
作者 赵世超 张亮亮 姜学鹏 王美娜 ZHAO Shi-chao;ZHANG Liang-liang;JIANG Xue-peng;WANG Mei-na(Jinan City Construction Group,Shandong Jinan 250000,China;Tunnel Design Institute,China Railway Siyuan Survey and Design Group Co.,Ltd.,Hubei Wuhan 430081,China;School of Resource and Environmental Engineering,Wuhan University of Science and Technology,Hubei Wuhan 430081,China)
出处 《消防科学与技术》 CAS 北大核心 2021年第9期1327-1331,共5页 Fire Science and Technology
基金 国家自然科学基金项目(51874213,51806156) 湖北省重点研发计划项目(2020BCB072)。
关键词 隧道火灾 公轨合建 人员疏散 数值模拟 tunnel fire road-rail tunnel evacuation numerical simulation
  • 相关文献

参考文献8

二级参考文献46

共引文献70

同被引文献55

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部